Klima Industries

Klima Motor Start Capacitor 72-86 µF 250 V

Motor start capacitor for motors that need 72-86 µF at 250 V. The sizes either side in this style are 64-77 and 80-96 µF.

Klima Capacitors · Model KC-MS-72-86

About this capacitor

For a capacitor-start motor whose data calls for 72-86 µF, this 250 V Klima capacitor is the replacement. It carries starting current for a second or two, which is why it is a different part from a run capacitor even when the µF figure looks similar.

The 72-86 µF window runs from 72 to 86 µF, about 19 % wide, and at its midpoint of 79 µF the capacitor presents roughly 40.3 ? at 50 Hz. A higher µF range passes more starting current through the auxiliary winding, which is why bigger motors, with more load to break away, are fitted with higher ranges.

Specifications

SpecificationValue
ModelKC-MS-72-86
Capacitance72-86 µF
Rated voltage250 VAC
TypeStart

Where it fits

  • Light conveyor and hoist drives on single-phase supplies
  • Single-phase compressors in air-conditioning and refrigeration plant that use a start capacitor and relay
  • Medium-size air compressors and workshop machinery
  • Replacements for a 250 V start capacitor of the same µF range

Fitting and checking

Match the µF range and the voltage class to the old capacitor or the motor data. A start capacitor in the 72-86 µF range should measure inside that window when new; read the old part out of circuit with a capacitance meter and replace it if it is below 72 µF. Discharge it first through a suitable resistor.

Compared with the other capacitors

Across the 116 models in Klima Capacitors, the values that vary are capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance72-86 µF0.5 to 480 µF
Rated voltage250 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run

In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 64-77 µF 250 V (64-77 µF) and the next step up is Klima Motor Start Capacitor 80-96 µF 250 V (80-96 µF). Quote the model code KC-MS-72-86 when you enquire so that the right size is supplied.

Questions

Which ranges sit either side of 72-86 µF?

Among the 250 V start capacitors the next range down is 64-77 µF and the next range up is 80-96 µF. Quote the range and the voltage class when you enquire.

Can I use a higher voltage rating than the original?

Yes. A higher voltage rating than the original is acceptable, provided the µF range matches and the case fits. A lower rating is not, because the capacitor would be overstressed at every start. This model is rated 250 V.

Why does my motor trip after the new start capacitor is fitted?

A tripped overload after fitting usually points to the wrong range, a relay that is not dropping out, or a wiring error rather than the capacitor. Check the µF range and the voltage against the motor data, confirm the relay or switch operates, and check that the wires are on the right terminals.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-72-86. For background reading, see the guide How to choose a run capacitor for an air conditioner.