Klima CBB65 Run Capacitor 10 µF

A 10 µF CBB65 run capacitor. It carries about 0.72 A at 230 V and 50 Hz. Quote the voltage you need with your enquiry.

Klima Capacitors · Model KC-C65-10

About this capacitor

Klima's CBB65 10 µF run capacitor is a single-section part for air-conditioner compressors and fan motors. CBB65 is the series designation usually given to sealed run capacitors of this kind, so the code is a quick way to tell the family apart from the CBB61 fan capacitors elsewhere in the range.

Think of 10 µF as an impedance of about 318 ? at 50 Hz (265 ? at 60 Hz). That impedance sets how much current reaches the auxiliary winding, and with it how much torque the motor develops. A capacitor that has lost capacity raises the impedance, and the motor shows it first as a slow start, extra heat or a tripped overload.

Specifications

SpecificationValue
ModelKC-C65-10
Capacitance10 µF
TypeSingle run

Where it fits

  • Single-phase booster and circulating pumps in HVAC plant rooms
  • Replacement of a bulged or leaking capacitor on an outdoor unit
  • Larger condenser fan motors on split and packaged air conditioners
  • Service work where a single-section part is needed beside a separate fan or compressor capacitor

Fitting and checking

Before replacing a 10 µF capacitor, confirm the fault. A fan or compressor that hums but will not start, or that starts slowly and runs hot, points to a weak capacitor, while a bulged or leaking case is a certain failure. After fitting, check that the motor current is within the nameplate value and listen for a smooth start.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance and type.

SpecificationThis modelAcross the range
Capacitance10 µF0.5 to 480 µF
TypeSingle runSingle run, Dual run, Start, Start/run

In the KC-C65 series, the next step down by capacitance is Klima CBB65 Run Capacitor 7.5 µF (7.5 µF) and the next step up is Klima CBB65 Run Capacitor 15 µF (15 µF). Quote the model code KC-C65-10 when you enquire so that the right size is supplied.

Questions

What is the next size up or down from 10 µF?

Within the CBB65 run capacitors the next size down is 7.5 µF and the next size up is 15 µF. Quote the voltage you need with the enquiry, because the voltage rating is confirmed from the old capacitor.

Is a CBB65 capacitor the same as a CBB61?

No. The two designations describe different families: CBB65 is the series usually given to sealed run capacitors for air-conditioner compressors and fan motors, while CBB61 is the series used for fan and small-motor capacitors, such as the 500 V AC parts listed elsewhere in this family. Match the µF value and the voltage of the old part rather than the series code alone.

Can a weak capacitor damage the motor?

It can. A motor that runs for long periods on a capacitor well below its rated value draws extra current and runs hot, which ages the insulation. If a 10 µF capacitor reads clearly low, replace it promptly instead of waiting for it to fail completely.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-C65-10. For background reading, see the guide How to choose a run capacitor for an air conditioner.