Buying capacitors in Bermuda
Bermuda is a compact market in North America, and its capital is Hamilton. Bermuda has a humid subtropical climate, with little variation across its small area. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
The main users of capacitors in Bermuda are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Bermuda.
- Capital
- Hamilton
- Population
- 64,000
- Area
- 53 km²
- Time zone
- UTC-4, moving to UTC-3 while daylight saving applies
- Climate
- Humid subtropical
- Supply
- 120 V, 60 Hz
- Main ports
- Hamilton
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Bermuda · Klima Capacitors overview
Conditions in Bermuda that affect capacitors
In Bermuda, cooling demand peaks through a long, humid summer. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Bermuda supplies 120 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
Mapping demand for capacitors in Bermuda
The directory lists one city for Bermuda: Hamilton, the capital, with about 902 people. Orders from anywhere in Bermuda are best quoted against it. Parts for Bermuda are best planned around Hamilton, which has a humid subtropical climate. In Hamilton, expect moisture on terminals and corrosion to show first on capacitors.
Size and settlement in Bermuda
The directory puts Bermuda at about 53 km², the 11th smallest of its 241 countries, almost exactly the size of Saint Martin (53 km²). Population density averages 1,207 people per km² across 64,000 residents, which is very densely settled and denser than 96% of the other countries in this directory. With sites this close, orders can be combined by city and delivered in a single run. For scale, the Cayman Islands has a similar number of people (64,000).
Time zone, sun and daylight in Bermuda
Local time in Hamilton is UTC-4, moving to UTC-3 while daylight saving applies.
At 32.3° N, Hamilton has about 14 h 16 min of daylight at the June solstice and about 10 h 02 min at the December solstice. The noon sun stands 81° above the horizon in June and 34° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.
Typical uses of capacitors in Bermuda
Typical work in Bermuda that needs capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Packaged rooftop units and ducted systems
- Fan coil unit and blower motors
- Ventilation and exhaust fan motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Bermuda
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Confirm the supply first: Bermuda uses 120 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Bermuda that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).
Care and maintenance in Bermuda
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check capacitors in Bermuda. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Approvals for capacitors sold into Bermuda
Klima capacitors are specified against IEC 60252-1 (AC motor capacitors). For import and installation in Bermuda, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.
Getting capacitors to Bermuda
Cargo for Bermuda usually arrives through Hamilton; tell us your preferred port or delivery address with your enquiry.
The local currency is the Dollar (BMD), so confirm the quotation currency and delivery terms before you order. The main languages are English and Portuguese; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Bermuda
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Bermuda?
The supply in Bermuda is 120 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.
Which standards apply to capacitors in Bermuda?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Bermuda the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Bermuda?
Sea freight into Bermuda normally clears through ports such as Hamilton, with onward delivery by road; urgent parts can travel by air.
Which city in Bermuda can I order capacitors for?
Hamilton (902) is the one city listed for Bermuda, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
What local time and daylight should I plan for in Bermuda?
Hamilton keeps UTC-4, moving to UTC-3 while daylight saving applies. At 32.3° N there are about 14 h 16 min of daylight in June and about 10 h 02 min in December.
More Klima products for Bermuda
- Klima Contactors in Bermuda
- Klima Terminal Crimps in Bermuda
- Klima Transformer for HVAC in Bermuda
- Klima Filter Driers in Bermuda
- Klima Condensate Pump in Bermuda
- Klima Delay on Make Timer in Bermuda