Klima Industries

Capacitors supply in Sudan

With about 41.8 million people, Sudan is a large national market in Africa. Its capital is Khartoum. The prevailing climate is hot and arid, though conditions differ between regions. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Capacitors are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Sudan for a quotation.

Capital
Khartoum
Population
41.8 million
Area
1,861,484 km²
Time zone
UTC+2 all year
Climate
Hot and arid
Supply
230 V, 50 Hz
Main ports
Port Sudan
Standards
SSMO (Sudanese Standards and Metrology Organization) requirements

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Sudan · Klima Capacitors overview

Capacitors and the climate in Sudan

In Sudan, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Dust and sand work their way into outdoor control boxes; closed covers, intact gaskets and regular cleaning keep capacitors cooler and connections reliable.

The mains supply in Sudan is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Capacitors across the cities of Sudan

The three largest listed cities (Khartoum, Omdurman and Khartoum North) hold about 46% of the people living in listed cities, which means there are a few big markets and a long tail of smaller ones. The widest gap between listed cities runs from Port Sudan to Al-Junaynah, about 1,716 km, so freight between the far ends takes days by road and urgent parts often go by air. The table lists the largest cities in Sudan with the climate stress that wears capacitors fastest in each.

CityPeopleClimateWhat wears capacitors first
Khartoum2 millionhot and aridterminals loosening and parts running hot
Omdurman1.8 millionhot and aridterminals loosening and parts running hot
Khartoum North1 millionhot and ariddust on contacts and blocked cooling
Nyala566,000hot and ariddust on contacts and blocked cooling
Kassala401,000hot and ariddust on contacts and blocked cooling
Wad Medani333,000hot and aridterminals loosening and parts running hot

The land and the people of Sudan

At roughly 1,861,484 km², Sudan is the 16th largest of the 241 countries covered by this directory, a little smaller than Indonesia (1,919,440 km²). With 41.8 million residents the average density is 22 per km², so Sudan counts as sparsely settled, sparser than 82% of the other countries in this directory. Sites can be a long way apart, so it is worth ordering a full set of spares for the season rather than one part at a time. For scale, Algeria has a similar number of people (42.2 million).

Mains supply across the borders of Sudan

Sudan borders South Sudan, Chad, Egypt, Ethiopia, Eritrea and 2 more. All of them use a nominal 230 V at 50 Hz, the same as Sudan, so an electrical rating that fits one side of the border fits the other.

Jobs in Sudan that call for capacitors

Typical work in Sudan that needs capacitors:

  • Split and window air conditioners
  • Fan coil unit and blower motors
  • Heat pump outdoor units
  • Ventilation and exhaust fan motors
  • Water pumps and booster sets used with HVAC plant

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round45 + 7.5440 / 370Dual run
Klima Motor Start Capacitor 64-77 µF 250 V64-77250Start
Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case216-259110 / 125Start
Klima CBB61 Start/Run Capacitor 4 µF 500 V AC4500Start/run
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Sudan

  • Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
  • Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
  • Confirm the supply first: Sudan uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
  • For hot and arid conditions in Sudan, favour higher temperature ratings and some margin on every rated value.

Care and maintenance in Sudan

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.

Sudan lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of capacitors for March or April, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Faults to watch for

  • Repeated overload trips, high running current or a unit that cuts out on hot afternoons

Which standards apply to capacitors in Sudan

Klima capacitors follow IEC 60252-1 (AC motor capacitors); in Sudan expect SSMO (Sudanese Standards and Metrology Organization) requirements as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Supply and delivery to Sudan

Sea freight into Sudan normally clears through ports such as Port Sudan, with onward delivery by road; urgent parts can travel by air.

The local currency is the Pound (SDG), so confirm the quotation currency and delivery terms before you order. The main languages are Arabic, English and Nobiin; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about capacitors in Sudan

Can I replace a capacitor with a higher µF value?

Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.

What voltage should capacitors be rated for in Sudan?

With a 230 V, 50 Hz supply, Sudan follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.

Which standards apply to capacitors in Sudan?

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Sudan the local framework is SSMO (Sudanese Standards and Metrology Organization) requirements; request the datasheet and conformity documents with your enquiry.

How are capacitors delivered to Sudan?

Cargo for Sudan usually arrives through Port Sudan; tell us your preferred port or delivery address with your enquiry.

Which cities in Sudan can I order capacitors for?

Every listed city is covered. The largest are Khartoum (2 million), Omdurman (1.8 million), Khartoum North (1 million), Nyala (566,000) and Port Sudan (490,000). The country page lists the rest.

What local time and daylight should I plan for in Sudan?

Khartoum keeps UTC+2 all year. At 15.6° N there are about 13 h 03 min of daylight in June and about 11 h 12 min in December.

Do the neighbours of Sudan use the same mains supply?

Yes. All 7 listed neighbours (South Sudan, Chad, Egypt, Ethiopia, Eritrea and 2 more) run on a nominal 230 V at 50 Hz, the same as Sudan, so the electrical rating of a part does not usually change at the border.

More Klima products for Sudan

Capacitors in cities across Sudan