Klima Industries

Klima Capacitors supplied to Madagascar

With about 26.3 million people, Madagascar is a mid-sized market in Africa. Its capital is Antananarivo. Most of the country has a highland climate, and conditions vary by region. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.

Demand for capacitors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Madagascar are welcome.

Capital
Antananarivo
Population
26.3 million
Area
587,040 km²
Time zone
UTC+3 all year
Climate
Highland
Supply
230 V, 50 Hz
Main ports
Toamasina
Standards
BNM (Bureau de Normes de Madagascar) requirements

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Madagascar · Klima Capacitors overview

Conditions in Madagascar that affect capacitors

In Madagascar, cooling demand is moderate, and refrigeration and process loads stay steady all year. Thinner air reduces convective cooling, so capacitors in outdoor panels run warmer than the same part at sea level; derate where the datasheet advises it.

Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.

Madagascar supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Where capacitors are needed in Madagascar

Antananarivo is both the capital and the largest listed city, with about 1.3 million people, so the capital is also the biggest single market. The widest gap between listed cities runs from Antsiranana to Ambovombe, about 1,469 km, so allow extra road time for the far end of the country. Climate decides how capacitors age, and it changes from city to city in Madagascar: the last column shows what to expect.

CityPeopleClimateWhat wears capacitors first
Antananarivo1.3 millionhighlandexpansion and contraction loosening joints
Toamasina345,000hot and humid tropicalterminals loosening and parts running hot
Antsirabe261,000hot and humid tropicalmoisture on terminals and corrosion
Mahajanga261,000hot and humid tropicalmoisture on terminals and corrosion
Fianarantsoa203,000hot and humid tropicalterminals loosening and parts running hot
Tolanaro71,000humid subtropicalmoisture on terminals and corrosion

The 28 listed cities fall into 3 climate types (24 hot and humid tropical, 3 humid subtropical and 1 highland), so parts are best chosen for the city where they will run.

The sun and the clock in Madagascar

Local time in Antananarivo is UTC+3 all year.

Antananarivo lies at 18.9° S, 47.5° E. Daylight lasts about 10 h 59 min at the June solstice and about 13 h 16 min in December, with a noon sun 48° and 85° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Jobs in Madagascar that call for capacitors

In Madagascar, these are the jobs that most often call for capacitors:

  • Heat pump outdoor units
  • Water pumps and booster sets used with HVAC plant
  • Split and window air conditioners
  • Packaged rooftop units and ducted systems
  • Fan coil unit and blower motors

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round45 + 7.5440 / 370Dual run
Klima Motor Start Capacitor 64-77 µF 250 V64-77250Start
Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case216-259110 / 125Start
Klima CBB61 Start/Run Capacitor 4 µF 500 V AC4500Start/run
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Madagascar

  • Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
  • Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
  • Confirm the supply first: Madagascar uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Madagascar that usually means BNM (Bureau de Normes de Madagascar) requirements.

Keeping capacitors reliable in Madagascar

  • Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.

Cooling demand at altitude in Madagascar is lower than in the lowlands but still real, and cold nights add refrigeration and heating work. Plan checks of capacitors at the change of season. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Faults to watch for

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Which standards apply to capacitors in Madagascar

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Madagascar, the local framework is BNM (Bureau de Normes de Madagascar) requirements, so match the datasheet to both and ask for any conformity documents your project needs.

Getting capacitors to Madagascar

Cargo for Madagascar usually arrives through Toamasina; tell us your preferred port or delivery address with your enquiry.

The local currency is the Ariary (MGA), so confirm the quotation currency and delivery terms before you order. The main languages are French and Malagasy; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Madagascar: common questions

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

What voltage should capacitors be rated for in Madagascar?

The mains supply in Madagascar is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to capacitors in Madagascar?

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Madagascar the local framework is BNM (Bureau de Normes de Madagascar) requirements; request the datasheet and conformity documents with your enquiry.

How are capacitors delivered to Madagascar?

Sea freight into Madagascar normally clears through ports such as Toamasina, with onward delivery by road; urgent parts can travel by air.

Which cities in Madagascar can I order capacitors for?

Every listed city is covered. The largest are Antananarivo (1.3 million), Toamasina (345,000), Antsirabe (261,000), Mahajanga (261,000) and Fianarantsoa (203,000). The country page lists the rest.

What local time and daylight should I plan for in Madagascar?

Antananarivo keeps UTC+3 all year. At 18.9° S there are about 10 h 59 min of daylight in June and about 13 h 16 min in December.

More Klima products for Madagascar

Capacitors in cities across Madagascar