Klima Capacitors in Guinea-Bissau
Guinea-Bissau is a smaller national market in Africa, and its capital is Bissau. The prevailing climate is hot and humid tropical, though conditions differ between regions. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Guinea-Bissau are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Guinea-Bissau for a quotation.
- Capital
- Bissau
- Population
- 1.9 million
- Area
- 36,120 km²
- Time zone
- UTC+0 all year
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
- Main ports
- Bissau
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Guinea-Bissau · Klima Capacitors overview
Capacitors and the climate in Guinea-Bissau
In Guinea-Bissau, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
With a 230 V, 50 Hz supply, Guinea-Bissau follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Cities that buy capacitors in Guinea-Bissau
The capital, Bissau, is also the largest listed city (about 440,000 people), which keeps most large buyers in one place. The two listed cities furthest apart, Bissau and Gabu, are about 157 km from each other in a straight line, which keeps most road deliveries inside a day. These are the biggest listed cities in Guinea-Bissau; the last column names what to watch for in capacitors there.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Bissau | 440,000 | hot and humid tropical | moisture on terminals and corrosion |
| Gabu | 49,000 | hot and humid tropical | moisture on terminals and corrosion |
| Bafata | 34,000 | hot and humid tropical | moisture on terminals and corrosion |
| Xitole | 19,000 | hot and humid tropical | terminals loosening and parts running hot |
Voltage next door: Guinea-Bissau and its neighbours
Guinea-Bissau borders Senegal and Guinea. Both use a nominal 230 V at 50 Hz, the same as Guinea-Bissau, so an electrical rating that fits one side of the border fits the other.
Time zone, sun and daylight in Guinea-Bissau
The clock in Bissau follows UTC+0 all year.
Sunlight at 11.9° N (Bissau): about 12 h 49 min of daylight in June, about 11 h 26 min in December, and a noon sun that reaches 78° in June and 55° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.
Where capacitors are used in Guinea-Bissau
In Guinea-Bissau, these are the jobs that most often call for capacitors:
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
- Fan coil unit and blower motors
- Ventilation and exhaust fan motors
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Guinea-Bissau
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Confirm the supply first: Guinea-Bissau uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For hot and humid tropical conditions in Guinea-Bissau, favour sealed, corrosion-resistant construction.
Care and maintenance in Guinea-Bissau
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
With little seasonal change in temperature, air conditioning in Guinea-Bissau works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Approvals for capacitors sold into Guinea-Bissau
Klima capacitors follow IEC 60252-1 (AC motor capacitors); in Guinea-Bissau expect applicable national electrical-safety and import conformity rules (generally IEC-based) as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.
Ordering capacitors for Guinea-Bissau
Cargo for Guinea-Bissau usually arrives through Bissau; tell us your preferred port or delivery address with your enquiry.
The local currency is the Franc (XOF), so confirm the quotation currency and delivery terms before you order. The main languages are Portuguese and Upper Guinea Crioulo; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Guinea-Bissau: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Guinea-Bissau?
Guinea-Bissau supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Which standards apply to capacitors in Guinea-Bissau?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Guinea-Bissau the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Guinea-Bissau?
Sea freight into Guinea-Bissau normally clears through ports such as Bissau, with onward delivery by road; urgent parts can travel by air.
Which cities in Guinea-Bissau can I order capacitors for?
Every listed city is covered. The largest are Bissau (440,000), Gabu (49,000), Bafata (34,000) and Xitole (19,000). The country page lists the rest.
Do the neighbours of Guinea-Bissau use the same mains supply?
Yes. Both listed neighbours (Senegal and Guinea) run on a nominal 230 V at 50 Hz, the same as Guinea-Bissau, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Guinea-Bissau?
Bissau keeps UTC+0 all year. At 11.9° N there are about 12 h 49 min of daylight in June and about 11 h 26 min in December.
More Klima products for Guinea-Bissau
- Klima Contactors in Guinea-Bissau
- Klima Terminal Crimps in Guinea-Bissau
- Klima Transformer for HVAC in Guinea-Bissau
- Klima Thermometers for HVAC in Guinea-Bissau
- Klima Condensate Pump in Guinea-Bissau
- Klima Filter Driers in Guinea-Bissau