Klima Industries

Klima Motor Start Capacitor 63-80 µF 250 V

Klima model KC-MS-63-80 is a 63-80 µF motor start capacitor rated 250 V. A weak start capacitor shows up as a slow or failed start.

Klima Capacitors · Model KC-MS-63-80

About this capacitor

Klima's 63-80 µF, 250 V start capacitor is built for short, repeated starting duty rather than for continuous running. The range figure is how start capacitors are specified: any reading inside 63 to 80 µF is a part performing as intended.

Stored energy deserves respect. At the 325 V peak of a 230 V supply a capacitor in the middle of this range (71.5 µF) holds about 3.78 J. Start capacitors are often fitted with a bleed resistor, but do not rely on it: discharge the terminals through a suitable resistor before you handle the part.

Specifications

SpecificationValue
ModelKC-MS-63-80
Capacitance63-80 µF
Rated voltage250 VAC
TypeStart

Where it fits

  • Concrete mixers, saw benches and similar loaded machinery
  • Pump motors that need several attempts to start on a weak supply
  • Medium-size air compressors and workshop machinery
  • Replacements for a 250 V start capacitor of the same µF range

Fitting and checking

After fitting, test the start sequence: the motor should accelerate promptly, the relay or switch should drop out, and the capacitor should stay cool to the touch once the motor is running. A part from the 63-80 µF range that is warm after a normal start points to a relay or switch fault.

Compared with the other capacitors

The 116 models in Klima Capacitors differ mainly in capacitance, rated voltage and type.

SpecificationThis modelAcross the range
Capacitance63-80 µF0.5 to 480 µF
Rated voltage250 VAC110 / 125, 220 / 250, 250, 330, 440, 440 / 370, 500 VAC
TypeStartSingle run, Dual run, Start, Start/run

In the KC-MS series, the next step down by capacitance is Klima Motor Start Capacitor 60-72 µF 250 V (60-72 µF) and the next step up is Klima Motor Start Capacitor 64-77 µF 250 V (64-77 µF). Quote the model code KC-MS-63-80 when you enquire so that the right size is supplied.

Questions

What is the next range up or down from 63-80 µF?

Among the 250 V start capacitors the next range down is 60-72 µF and the next range up is 64-77 µF. Quote the range and the voltage class when you enquire.

What is the difference between 250 V and 330 V start capacitors?

Both are used on 220-240 V motors; the 330 V class has more voltage margin. A 330 V part can replace a 250 V one of the same µF range, but not the reverse. This 63-80 µF model is the 250 V class.

How do I tell whether the start capacitor has failed?

A motor that hums but does not turn, takes a long time to reach speed or trips its overload on start often has a failed start capacitor. Isolate and discharge the part and read it with a capacitance meter: a reading below 63 µF on a 63-80 µF part means it has lost capacity. A bulged, split or leaking case is an immediate fail.

Selection, care and fault-finding notes for the whole family are on the Klima Capacitors page, and the contact page takes enquiries with the model code KC-MS-63-80. For background reading, see the guide How to choose a run capacitor for an air conditioner.