Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Botswana · Klima Capacitors overview
Capacitors and the climate in Botswana
In Botswana, air conditioning and refrigeration run for most of the year. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Fine dust settles on capacitors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
The mains supply in Botswana is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Capacitors across the cities of Botswana
Together Gaborone, Francistown and Maun account for roughly 47% of the population of all listed cities, so demand is shared between a few large centres and many smaller cities. From Maun to Lobatse, the longest straight-line gap between listed cities is about 627 km; so delivery to the far end of the country is a long road journey. The table lists the largest cities in Botswana with the climate stress that wears capacitors fastest in each.
| City | People | Climate | What wears capacitors first |
|---|---|---|---|
| Gaborone | 246,000 | hot and arid | terminals loosening and parts running hot |
| Francistown | 103,000 | hot and arid | dust on contacts and blocked cooling |
| Maun | 85,000 | hot and arid | terminals loosening and parts running hot |
| Serowe | 56,000 | hot and arid | terminals loosening and parts running hot |
| Mahalapye | 48,000 | hot and arid | dust on contacts and blocked cooling |
| Kanye | 48,000 | hot and arid | terminals loosening and parts running hot |
Every one of the 14 listed cities has a hot and arid climate, which keeps the choice of parts consistent from city to city.
Botswana in numbers
Botswana covers about 600,370 km², the 46th largest of the 241 countries in this directory, almost exactly the size of Ukraine (603,700 km²). Its 2.3 million people give an average of 3.8 per km². In this directory that is sparsely settled, sparser than 95% of the other countries in this directory. Sites can be a long way apart, so it is worth ordering a full set of spares for the season rather than one part at a time. For scale, the Gambia has a similar number of people (2.3 million).
Neighbouring supplies to check before ordering capacitors
Botswana borders Zimbabwe, South Africa and Namibia. All of them use a nominal 230 V at 50 Hz, the same as Botswana, so an electrical rating that fits one side of the border fits the other.
Typical uses of capacitors in Botswana
In Botswana, these are the jobs that most often call for capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
- Commercial display fridges and freezers
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round | 45 + 7.5 | 440 / 370 | Dual run |
| Klima Motor Start Capacitor 64-77 µF 250 V | 64-77 | 250 | Start |
| Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case | 216-259 | 110 / 125 | Start |
| Klima CBB61 Start/Run Capacitor 4 µF 500 V AC | 4 | 500 | Start/run |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Botswana
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Confirm the supply first: Botswana uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
- For hot and arid conditions in Botswana, favour higher temperature ratings and some margin on every rated value.
Care and maintenance in Botswana
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Botswana is in the southern hemisphere, the heaviest cooling load normally falls from November to March. Service capacitors in September or October, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Approvals for capacitors sold into Botswana
Two sets of rules apply to capacitors sold into Botswana: the product standard, IEC 60252-1 (AC motor capacitors), and the local one, BOBS (Botswana Bureau of Standards) requirements. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Ordering capacitors for Botswana
As a landlocked market, Botswana receives sea freight through a transit port in a neighbouring country (Zimbabwe, South Africa and Namibia); air freight is the faster option for urgent parts.
The local currency is the Pula (BWP), so confirm the quotation currency and delivery terms before you order. The main languages are English and Tswana; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Botswana
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Botswana?
With a 230 V, 50 Hz supply, Botswana follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
Which standards apply to capacitors in Botswana?
Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Botswana the local framework is BOBS (Botswana Bureau of Standards) requirements; request the datasheet and conformity documents with your enquiry.
How are capacitors delivered to Botswana?
Botswana has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Zimbabwe, South Africa and Namibia and continues inland by road or rail; allow extra time for transit and border handling.
Which cities in Botswana can I order capacitors for?
Every listed city is covered. The largest are Gaborone (246,000), Francistown (103,000), Maun (85,000), Molepolole (75,000) and Serowe (56,000). The country page lists the rest.
Do the neighbours of Botswana use the same mains supply?
Yes. All 3 listed neighbours (Zimbabwe, South Africa and Namibia) run on a nominal 230 V at 50 Hz, the same as Botswana, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Botswana?
Gaborone keeps UTC+2 all year. At 24.7° S there are about 10 h 36 min of daylight in June and about 13 h 40 min in December.
More Klima products for Botswana
- Klima Contactors in Botswana
- Klima Terminal Crimps in Botswana
- Klima Transformer for HVAC in Botswana
- Klima Thermostats in Botswana
- Klima Cables (3 & 4 Core) in Botswana
- Klima Drier Core 48-KL in Botswana