Klima Contactors supplied to Botswana
Botswana is a smaller national market in Africa, and its capital is Gaborone. The prevailing climate is hot and arid, though conditions differ between regions. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Contactors are bought here mainly for offices, shops and malls, homes and apartments as well as hospitals and clinics. The range below has 7 models; send an enquiry with the model code and your delivery address in Botswana.
- Capital
- Gaborone
- Population
- 2.3 million
- Area
- 600,370 km²
- Time zone
- UTC+2 all year
- Climate
- Hot and arid
- Supply
- 230 V, 50 Hz
- Standards
- BOBS (Botswana Bureau of Standards) requirements
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Botswana · Klima Contactors overview
Contactors and the climate in Botswana
In Botswana, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Fine dust settles on contactors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
With a 230 V, 50 Hz supply, Botswana follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.
Where contactors are needed in Botswana
About 47% of the people in listed cities live in Gaborone, Francistown and Maun; demand is shared between a few large centres and many smaller cities. Gaborone is both the capital and the largest listed city, with about 246,000 people, so the capital is also the biggest single market. The table lists the largest cities in Botswana with the climate stress that wears contactors fastest in each.
| City | People | Climate | What wears contactors first |
|---|---|---|---|
| Gaborone | 246,000 | hot and arid | terminals loosening and parts running hot |
| Francistown | 103,000 | hot and arid | terminals loosening and parts running hot |
| Maun | 85,000 | hot and arid | terminals loosening and parts running hot |
| Molepolole | 75,000 | hot and arid | terminals loosening and parts running hot |
| Serowe | 56,000 | hot and arid | terminals loosening and parts running hot |
| Selebi-Phikwe | 42,000 | hot and arid | dust on contacts and blocked cooling |
The sun and the clock in Botswana
The clock in Gaborone follows UTC+2 all year.
Sunlight at 24.7° S (Gaborone): about 10 h 36 min of daylight in June, about 13 h 40 min in December, and a noon sun that reaches 42° in June and 89° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.
The land and the people of Botswana
Botswana covers about 600,370 km², the 46th largest of the 241 countries in this directory, almost exactly the size of Ukraine (603,700 km²). With 2.3 million residents the average density is 3.8 per km², so Botswana counts as sparsely settled, sparser than 95% of the other countries in this directory. Sites can be a long way apart, so it is worth ordering a full set of spares for the season rather than one part at a time. For scale, the Gambia has a similar number of people (2.3 million).
Jobs in Botswana that call for contactors
Typical work in Botswana that needs contactors:
- Compressor control in split and packaged air conditioners
- Heat pump defrost and reversing controls
- Chiller and air handling unit starter panels
- Condenser fan switching
- Walk-in cold rooms and refrigerated display cases
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Botswana
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Confirm the supply first: Botswana uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- For hot and arid conditions in Botswana, favour higher temperature ratings and some margin on every rated value.
Care and maintenance in Botswana
- Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.
Because Botswana is in the southern hemisphere, the heaviest cooling load normally falls from November to March. Service contactors in September or October, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- A compressor that will not start although the thermostat is calling for cooling
Approvals for contactors sold into Botswana
Two sets of rules apply to contactors sold into Botswana: the product standard, IEC 60947-4-1 (contactors and motor-starters), and the local one, BOBS (Botswana Bureau of Standards) requirements. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Ordering contactors for Botswana
As a landlocked market, Botswana receives sea freight through a transit port in a neighbouring country (Zimbabwe, South Africa and Namibia); air freight is the faster option for urgent parts.
The local currency is the Pula (BWP), so confirm the quotation currency and delivery terms before you order. The main languages are English and Tswana; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Contactors in Botswana: common questions
What coil voltage should I choose?
Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.
What voltage should contactors be rated for in Botswana?
Botswana supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Which standards apply to contactors in Botswana?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Botswana the local framework is BOBS (Botswana Bureau of Standards) requirements; request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Botswana?
Botswana has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Zimbabwe, South Africa and Namibia and continues inland by road or rail; allow extra time for transit and border handling.
Which cities in Botswana can I order contactors for?
Every listed city is covered. The largest are Gaborone (246,000), Francistown (103,000), Maun (85,000), Molepolole (75,000) and Serowe (56,000). The country page lists the rest.
Do the neighbours of Botswana use the same mains supply?
Yes. All 3 listed neighbours (Zimbabwe, South Africa and Namibia) run on a nominal 230 V at 50 Hz, the same as Botswana, so the electrical rating of a part does not usually change at the border.
What local time and daylight should I plan for in Botswana?
Gaborone keeps UTC+2 all year. At 24.7° S there are about 10 h 36 min of daylight in June and about 13 h 40 min in December.
More Klima products for Botswana
- Klima Capacitors in Botswana
- Klima Delay on Make Timer in Botswana
- Klima Transformer for HVAC in Botswana
- Klima Thermostat Guards in Botswana
- Klima Terminal Crimps in Botswana
- Klima PVC Tapes in Botswana