Capacitors supply in Molepolole
With about 75,000 people, Molepolole is a smaller city in Botswana. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Demand for capacitors comes mostly from offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Molepolole are welcome.
- Country
- Botswana
- Population
- 75,000
- Climate
- Hot and arid
- Coordinates
- 24.4° S, 25.5° E
- Time zone
- UTC+2 all year
- From Gaborone
- 50 km north-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Molepolole · Klima Capacitors overview
What Molepolole demands of capacitors
In Molepolole, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Fine dust settles on capacitors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
Capacitors in Molepolole and the cities near it
Molepolole ranks 4th of the 14 listed cities in Botswana and holds about 8% of the people living in them, about 30% of the size of Gaborone, the largest. Molepolole lies about 50 km north-west of Gaborone, the capital. It is about the same size as Gavle in Sweden, which has 75,000.
Nearest to Molepolole: Thamaga (30 km south), Gaborone (50 km south-east) and Kanye (64 km south). Six other listed cities lie within 100 km, and nine within 300 km. At the other extreme, Maun is about 536 km north-west of Molepolole, the furthest listed city in Botswana.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Thamaga | 30 km south | 25,000 | terminals loosening and parts running hot |
| Gaborone | 50 km south-east | 246,000 | dust on contacts and blocked cooling |
| Kanye | 64 km south | 48,000 | dust on contacts and blocked cooling |
| Ramotswa | 64 km south-east | 33,000 | terminals loosening and parts running hot |
| Mochudi | 66 km east | 50,000 | dust on contacts and blocked cooling |
| Lobatse | 93 km south | 30,000 | terminals loosening and parts running hot |
In a smaller city like Molepolole, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Molepolole
The clock in Molepolole follows UTC+2 all year.
Molepolole lies at 24.4° S, 25.5° E. Daylight lasts about 10 h 37 min at the June solstice and about 13 h 39 min in December, with a noon sun 42° and 89° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Molepolole is hot and arid, in line with the rest of Botswana; 13 other listed cities share it.
Jobs in Molepolole that call for capacitors
Typical work in Molepolole that needs capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Molepolole
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- For hot and arid conditions in Molepolole, favour higher temperature ratings and some margin on every rated value.
Keeping capacitors reliable in Molepolole
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Molepolole is in the southern hemisphere, the heaviest cooling load normally falls from November to March. Service capacitors in September or October, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A swollen, bulging or leaking case
Getting capacitors to Molepolole
Shipments for Molepolole normally clear customs at one of the main entry points of Botswana and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Botswana are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Molepolole: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Molepolole?
The mains supply in Botswana is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Molepolole?
To order capacitors for Molepolole, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Molepolole can I order for?
Enquiries are welcome from every part of Molepolole. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Molepolole?
Molepolole keeps UTC+2 all year. At 24.4° S there are about 10 h 37 min of daylight in June and about 13 h 39 min in December.
Which cities near Molepolole can the same order serve?
The listed cities closest to Molepolole are Thamaga (30 km south), Gaborone (50 km south-east) and Kanye (64 km south). Combine them into one order and give each delivery address.
More Klima products for Molepolole
- Klima Contactors in Molepolole
- Klima Terminal Crimps in Molepolole
- Klima Transformer for HVAC in Molepolole
- Klima Delay on Make Timer in Molepolole
- Klima PVC Tapes in Molepolole
- Klima Thermometers for HVAC in Molepolole