Klima Industries

Buying capacitors in Barbados

Home to about 287,000 people, Barbados sits in North America. Its capital is Bridgetown. Across Barbados the climate is hot and humid tropical, and conditions are similar from place to place. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of capacitors in Barbados are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Barbados for a quotation.

Capital
Bridgetown
Population
287,000
Area
431 km²
Time zone
UTC-4 all year
Climate
Hot and humid tropical
Supply
115 V, 50 Hz
Main ports
Bridgetown
Standards
BNSI (Barbados National Standards Institution) requirements

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Barbados · Klima Capacitors overview

Capacitors and the climate in Barbados

In Barbados, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Barbados supplies 115 V at 50 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.

Mapping demand for capacitors in Barbados

The directory lists one city for Barbados: Bridgetown, the capital, with about 99,000 people. Orders from anywhere in Barbados are best quoted against it. Parts for Barbados are best planned around Bridgetown, which has a hot and humid tropical climate. For capacitors in Bridgetown, watch for moisture on terminals and corrosion before anything else.

Time zone, sun and daylight in Barbados

Local time in Bridgetown is UTC-4 all year.

Bridgetown lies at 13.1° N, 59.6° W. Daylight lasts about 12 h 54 min at the June solstice and about 11 h 21 min in December, with a noon sun 80° and 53° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Where capacitors are used in Barbados

Typical work in Barbados that needs capacitors:

  • Fan coil unit and blower motors
  • Split and window air conditioners
  • Packaged rooftop units and ducted systems
  • Heat pump outdoor units
  • Ventilation and exhaust fan motors

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Dual Run Capacitor 45+7.5 µF 440/370 V, Round45 + 7.5440 / 370Dual run
Klima Motor Start Capacitor 64-77 µF 250 V64-77250Start
Klima Start Capacitor 216-259 µF 110/125 V, Round Phenolic Case216-259110 / 125Start
Klima CBB61 Start/Run Capacitor 4 µF 500 V AC4500Start/run
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Barbados

  • Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
  • Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
  • Confirm the supply first: Barbados uses 115 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Barbados that usually means BNSI (Barbados National Standards Institution) requirements.

Keeping capacitors reliable in Barbados

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.

A tropical climate keeps cooling demand steady through the year in Barbados, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Faults to watch for

  • Repeated overload trips, high running current or a unit that cuts out on hot afternoons

Standards and paperwork for capacitors in Barbados

Klima capacitors are specified against IEC 60252-1 (AC motor capacitors). For import and installation in Barbados, buyers also meet BNSI (Barbados National Standards Institution) requirements. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Supply and delivery to Barbados

Sea freight into Barbados normally clears through ports such as Bridgetown, with onward delivery by road; urgent parts can travel by air.

The local currency is the Dollar (BBD), so confirm the quotation currency and delivery terms before you order. The main languages are English; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Capacitors in Barbados: common questions

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

What voltage should capacitors be rated for in Barbados?

The supply in Barbados is 115 V, 50 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.

Which standards apply to capacitors in Barbados?

Klima capacitors follow IEC 60252-1 (AC motor capacitors). In Barbados the local framework is BNSI (Barbados National Standards Institution) requirements; request the datasheet and conformity documents with your enquiry.

How are capacitors delivered to Barbados?

Cargo for Barbados usually arrives through Bridgetown; tell us your preferred port or delivery address with your enquiry.

Which city in Barbados can I order capacitors for?

Bridgetown (99,000) is the one city listed for Barbados, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.

What local time and daylight should I plan for in Barbados?

Bridgetown keeps UTC-4 all year. At 13.1° N there are about 12 h 54 min of daylight in June and about 11 h 21 min in December.

More Klima products for Barbados

Capacitors in cities across Barbados