Contactors supply in Austria
With about 8.8 million people, Austria is a mid-sized market in Europe. Its capital is Vienna. Most of the country has a temperate climate, and conditions vary by region. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
Contactors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The range below has 7 models; send an enquiry with the model code and your delivery address in Austria.
- Capital
- Vienna
- Population
- 8.8 million
- Area
- 83,858 km²
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- Climate
- Temperate
- Supply
- 230 V, 50 Hz
- Standards
- CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Austria · Klima Contactors overview
Contactors and the climate in Austria
In Austria, cooling demand is seasonal, with short hot spells that stress equipment. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.
Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
The mains supply in Austria is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Cities that buy contactors in Austria
From Vienna to Feldkirch, the longest straight-line gap between listed cities is about 518 km; so delivery to the far end of the country is a long road journey. The three largest listed cities (Vienna, Graz and Linz) hold about 73% of the people living in listed cities, which means buyers are concentrated in a few centres. These are the biggest listed cities in Austria; the last column names what to watch for in contactors there.
| City | People | Climate | What wears contactors first |
|---|---|---|---|
| Vienna | 1.7 million | temperate | moisture on terminals and corrosion |
| Graz | 303,000 | temperate | moisture on terminals and corrosion |
| Linz | 205,000 | temperate | expansion and contraction loosening joints |
| Klagenfurt am Worthersee | 100,000 | temperate | expansion and contraction loosening joints |
| Eisenzicken | 54,000 | temperate | expansion and contraction loosening joints |
| Dornbirn | 49,000 | temperate | moisture on terminals and corrosion |
Every one of the 20 listed cities has a temperate climate, which keeps the choice of parts consistent from city to city.
The land and the people of Austria
By land area Austria is the 116th largest of the 241 places listed here, at roughly 83,858 km², almost exactly the size of the United Arab Emirates (82,880 km²). With 8.8 million residents the average density is 106 per km², so Austria counts as densely settled, denser than 58% of the other countries in this directory. Most sites sit within reach of a city, so deliveries can usually be planned city by city. For scale, Israel has a similar number of people (8.9 million).
Time zone, sun and daylight in Austria
The clock in Vienna follows UTC+1, moving to UTC+2 while daylight saving applies.
Vienna lies at 48.2° N, 16.4° E. Daylight lasts about 16 h 05 min at the June solstice and about 8 h 20 min in December, with a noon sun 65° and 18° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat.
Where contactors are used in Austria
Typical work in Austria that needs contactors:
- Heater banks and electric reheat
- Compressor control in split and packaged air conditioners
- Condenser fan switching
- Chiller and air handling unit starter panels
- Heat pump defrost and reversing controls
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Austria
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Confirm the supply first: Austria uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Austria that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.
Keeping contactors reliable in Austria
- Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.
Because Austria is in the northern hemisphere, the heaviest cooling load normally falls in July and August. Service contactors in May or June, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Burnt or welded contacts that keep the unit running when switched off
Standards and paperwork for contactors in Austria
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Austria, the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations, so match the datasheet to both and ask for any conformity documents your project needs.
Ordering contactors for Austria
As a landlocked market, Austria receives sea freight through a transit port in a neighbouring country (Switzerland, Germany, Hungary and Slovakia); air freight is the faster option for urgent parts.
The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are German, Croatian, Hungarian and Slovenian; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about contactors in Austria
What does the number of poles mean?
A pole is one switched circuit. A 2-pole contactor breaks both line wires of a single-phase supply, while a 3-pole contactor breaks all three phases of a three-phase supply.
What voltage should contactors be rated for in Austria?
With a 230 V, 50 Hz supply, Austria follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.
Which standards apply to contactors in Austria?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Austria the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Austria?
Austria has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Switzerland, Germany, Hungary and Slovakia and continues inland by road or rail; allow extra time for transit and border handling.
Which cities in Austria can I order contactors for?
Every listed city is covered. The largest are Vienna (1.7 million), Graz (303,000), Linz (205,000), Salzburg (157,000) and Innsbruck (132,000). The country page lists the rest.
What local time and daylight should I plan for in Austria?
Vienna keeps UTC+1, moving to UTC+2 while daylight saving applies. At 48.2° N there are about 16 h 05 min of daylight in June and about 8 h 20 min in December.
Do the neighbours of Austria use the same mains supply?
Yes. All 8 listed neighbours (Switzerland, Germany, Hungary, Slovakia, the Czech Republic and 3 more) run on a nominal 230 V at 50 Hz, the same as Austria, so the electrical rating of a part does not usually change at the border.
More Klima products for Austria
- Klima Capacitors in Austria
- Klima Delay on Make Timer in Austria
- Klima Transformer for HVAC in Austria
- Klima Copper Coils & Tubes in Austria
- Klima Thermometers for HVAC in Austria
- Klima Thermostat Guards in Austria