Contactors for Kiribati
Home to about 116,000 people, Kiribati sits in Oceania. Its capital is Tarawa. Kiribati has a hot and humid tropical climate, with little variation across its small area. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of contactors in Kiribati are offices, shops and malls as well as factories and workshops. The Klima range includes 7 models, each with a specification table; send an enquiry from Kiribati for a quotation.
- Capital
- Tarawa
- Population
- 116,000
- Area
- 811 km²
- Time zone
- UTC+12 all year
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
- Main ports
- Betio
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Kiribati · Klima Contactors overview
Conditions in Kiribati that affect contactors
In Kiribati, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Kiribati supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Mapping demand for contactors in Kiribati
The directory lists one city for Kiribati: Tarawa, the capital, with about 40,000 people. Orders from anywhere in Kiribati are best quoted against it. With a single listed city, the stocking plan for Kiribati follows one set of conditions, a hot and humid tropical climate in Tarawa. For contactors in Tarawa, watch for terminals loosening and parts running hot before anything else.
Daylight, sun angle and time in Kiribati
Tarawa keeps UTC+12 all year.
Sunlight at 1.3° N (Tarawa): about 12 h 12 min of daylight in June, about 12 h 03 min in December, and a noon sun that reaches 68° in June and 65° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat.
Size and settlement in Kiribati
The directory puts Kiribati at about 811 km², the 54th smallest of its 241 countries. With 116,000 residents the average density is 143 per km², so Kiribati counts as densely settled, denser than 66% of the other countries in this directory. The land area is small, so road distances on any one island are short; for island groups, say which island a delivery is for. Its population is similar to that of Micronesia (113,000).
Where contactors are used in Kiribati
Typical work in Kiribati that needs contactors:
- Compressor control in split and packaged air conditioners
- Lighting and general power switching in plant rooms
- Heat pump defrost and reversing controls
- Heater banks and electric reheat
- Condenser fan switching
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Kiribati
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Confirm the supply first: Kiribati uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Kiribati that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).
Care and maintenance in Kiribati
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
With little seasonal change in temperature, air conditioning in Kiribati works almost every day. Spread checks of contactors through the year instead of waiting for a peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- Burnt or welded contacts that keep the unit running when switched off
Which standards apply to contactors in Kiribati
Klima contactors are specified against IEC 60947-4-1 (contactors and motor-starters). For import and installation in Kiribati, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.
Getting contactors to Kiribati
Sea freight into Kiribati normally clears through ports such as Betio, with onward delivery by road; urgent parts can travel by air.
The local currency is the Dollar (AUD), so confirm the quotation currency and delivery terms before you order. The main languages are English and Gilbertese; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about contactors in Kiribati
Is a contactor the same as a relay?
They work the same way, but contactors are built for higher currents and repeated switching of motor loads, whereas relays handle small control currents.
What voltage should contactors be rated for in Kiribati?
The mains supply in Kiribati is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Which standards apply to contactors in Kiribati?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Kiribati the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Kiribati?
Cargo for Kiribati usually arrives through Betio; tell us your preferred port or delivery address with your enquiry.
Which city in Kiribati can I order contactors for?
Tarawa (40,000) is the one city listed for Kiribati, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
What local time and daylight should I plan for in Kiribati?
Tarawa keeps UTC+12 all year. At 1.3° N there are about 12 h 12 min of daylight in June and about 12 h 03 min in December.
More Klima products for Kiribati
- Klima Capacitors in Kiribati
- Klima Delay on Make Timer in Kiribati
- Klima Transformer for HVAC in Kiribati
- Klima Terminal Crimps in Kiribati
- Klima Pressure Switches (High & Low) in Kiribati
- Klima Thermostat Guards in Kiribati