Contactors for Nauru
Nauru is a compact market in Oceania, and its capital is Yaren. The climate across Nauru is hot and humid tropical, with only modest differences from one place to another. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Contactors are bought here mainly for offices, shops and malls as well as factories and workshops. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Nauru are welcome.
- Capital
- Yaren
- Population
- 13,000
- Area
- 21 km²
- Time zone
- UTC+12 all year
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Nauru · Klima Contactors overview
Contactors and the climate in Nauru
In Nauru, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
The mains supply in Nauru is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Contactors across the cities of Nauru
Yaren, the capital, is the only city listed for Nauru, with about 1,100 people, so every enquiry from the country can be tied to one place. Parts for Nauru are best planned around Yaren, which has a hot and humid tropical climate. In Yaren, expect terminals loosening and parts running hot to show first on contactors.
Nauru in numbers
By land area Nauru is the 6th smallest of the 241 places listed here, at roughly 21 km², almost exactly the size of Saint Barthelemy (21 km²). Population density averages 605 people per km² across 13,000 residents, which is very densely settled and denser than 92% of the other countries in this directory. With sites this close, orders can be combined by city and delivered in a single run. In population it sits close to Anguilla, which has about 13,000.
Jobs in Nauru that call for contactors
Contactors are most often specified in Nauru for:
- Chiller and air handling unit starter panels
- Heat pump defrost and reversing controls
- Lighting and general power switching in plant rooms
- Compressor control in split and packaged air conditioners
- Condenser fan switching
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing contactors for Nauru
- Pick the right pole count: 2-pole for single-phase units where both lines must break, 3-pole for three-phase compressors.
- Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
- Confirm the supply first: Nauru uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- For hot and humid tropical conditions in Nauru, favour sealed, corrosion-resistant construction.
Care and maintenance in Nauru
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
With little seasonal change in temperature, air conditioning in Nauru works almost every day. Spread checks of contactors through the year instead of waiting for a peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Burnt or welded contacts that keep the unit running when switched off
Approvals for contactors sold into Nauru
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Nauru, the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based), so match the datasheet to both and ask for any conformity documents your project needs.
Getting contactors to Nauru
Freight reaches Nauru by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.
The local currency is the Dollar (AUD), so confirm the quotation currency and delivery terms before you order. The main languages are Nauru and English; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about contactors in Nauru
How often should contactors be replaced?
There is no fixed interval. Replace them when the contacts show pitting or heat discolouration, or at the first sign of intermittent starting. Frequent cycling shortens life.
What voltage should contactors be rated for in Nauru?
With a 230 V, 50 Hz supply, Nauru follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.
Which standards apply to contactors in Nauru?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Nauru the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Nauru?
Freight reaches Nauru by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.
Which city in Nauru can I order contactors for?
Yaren (1,100) is the one city listed for Nauru, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
What local time and daylight should I plan for in Nauru?
Yaren keeps UTC+12 all year. At 0.6° S there are about 12 h 05 min of daylight in June and about 12 h 09 min in December.
More Klima products for Nauru
- Klima Capacitors in Nauru
- Klima Delay on Make Timer in Nauru
- Klima Transformer for HVAC in Nauru
- Klima Copper Coils & Tubes in Nauru
- Klima Condensate Pump in Nauru
- Klima Filter Driers in Nauru