Klima Industries

Klima Contactors in Bahrain

Bahrain is a smaller national market in Asia, and its capital is Manama. Across Bahrain the climate is hot and arid, and conditions are similar from place to place. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Demand for contactors comes mostly from offices, shops and malls as well as homes and apartments. The range below has 7 models; send an enquiry with the model code and your delivery address in Bahrain.

Capital
Manama
Population
1.6 million
Area
665 km²
Time zone
UTC+3 all year
Climate
Hot and arid
Supply
230 V, 50 Hz
Main ports
Khalifa Bin Salman Port
Standards
GSO-based standards and Bahrain conformity requirements

Klima Contactors models

All Klima products for Bahrain · Klima Contactors overview

Contactors and the climate in Bahrain

In Bahrain, air conditioning and refrigeration run for most of the year. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Fine dust settles on contactors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.

With a 230 V, 50 Hz supply, Bahrain follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

Cities that buy contactors in Bahrain

Manama, the capital, lies about 4 km south-west of Muharraq, which is the largest listed city, so say which of the two cities a delivery is for. The three largest listed cities (Muharraq, Manama and Madinat Hamad) hold about 64% of the people living in listed cities, which means a few centres do most of the buying. Climate decides how contactors age, and it changes from city to city in Bahrain: the last column shows what to expect.

CityPeopleClimateWhat wears contactors first
Muharraq177,000hot and aridterminals loosening and parts running hot
Manama147,000hot and ariddust on contacts and blocked cooling
Madinat Hamad134,000hot and ariddust on contacts and blocked cooling
Ar Rifa'115,000hot and ariddust on contacts and blocked cooling
Sitrah73,000hot and ariddust on contacts and blocked cooling
Dar Kulayb65,000hot and aridterminals loosening and parts running hot

All 6 listed cities share a hot and arid climate, so one stocking plan covers the whole country.

The land and the people of Bahrain

At roughly 665 km², Bahrain is the 49th smallest of the 241 countries covered by this directory, a little smaller than Singapore (692 km²). With 1.6 million residents the average density is 2,360 per km², so Bahrain counts as very densely settled, denser than 98% of the other countries in this directory. With sites this close, orders can be combined by city and delivered in a single run.

Daylight, sun angle and time in Bahrain

The clock in Manama follows UTC+3 all year.

Manama lies at 26.2° N, 50.6° E. Daylight lasts about 13 h 47 min at the June solstice and about 10 h 30 min in December, with a noon sun 87° and 40° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Where contactors are used in Bahrain

Typical work in Bahrain that needs contactors:

  • Compressor control in split and packaged air conditioners
  • Chiller and air handling unit starter panels
  • Heat pump defrost and reversing controls
  • Pump and ventilation motor control
  • Hotel fan coil and VRF outdoor unit panels

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick contactors for work in Bahrain

  • Check whether the control logic needs auxiliary NO or NC contacts for feedback.
  • Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
  • Confirm the supply first: Bahrain uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • For hot and arid conditions in Bahrain, favour higher temperature ratings and some margin on every rated value.

Keeping contactors reliable in Bahrain

  • Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.

Because Bahrain is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service contactors in March or April, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Signs of trouble

  • A compressor that will not start although the thermostat is calling for cooling

Which standards apply to contactors in Bahrain

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters); in Bahrain expect GSO-based standards and Bahrain conformity requirements as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering contactors for Bahrain

Sea freight into Bahrain normally clears through ports such as Khalifa Bin Salman Port, with onward delivery by road; urgent parts can travel by air.

The local currency is the Dinar (BHD), so confirm the quotation currency and delivery terms before you order. The main languages are Arabic, English, Persian and Urdu; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Contactors in Bahrain: common questions

What coil voltage should I choose?

Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.

What voltage should contactors be rated for in Bahrain?

Bahrain supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to contactors in Bahrain?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Bahrain the local framework is GSO-based standards and Bahrain conformity requirements; request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Bahrain?

Cargo for Bahrain usually arrives through Khalifa Bin Salman Port; tell us your preferred port or delivery address with your enquiry.

Which cities in Bahrain can I order contactors for?

Every listed city is covered. The largest are Muharraq (177,000), Manama (147,000), Madinat Hamad (134,000), Ar Rifa' (115,000) and Sitrah (73,000). The country page lists the rest.

What local time and daylight should I plan for in Bahrain?

Manama keeps UTC+3 all year. At 26.2° N there are about 13 h 47 min of daylight in June and about 10 h 30 min in December.

More Klima products for Bahrain

Contactors in cities across Bahrain