Klima Industries

Contactors for Namibia

Namibia is a smaller national market in Africa, and its capital is Windhoek. Most of the country has a hot and arid climate, and conditions vary by region. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Contactors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 7 models, each with a specification table; send an enquiry from Namibia for a quotation.

Capital
Windhoek
Population
2.4 million
Area
825,418 km²
Time zone
UTC+2 all year
Climate
Hot and arid
Supply
230 V, 50 Hz
Main ports
Walvis Bay
Standards
NSI (Namibian Standards Institution) requirements

Klima Contactors models

All Klima products for Namibia · Klima Contactors overview

Contactors and the climate in Namibia

In Namibia, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Fine dust settles on contactors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.

The mains supply in Namibia is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Mapping demand for contactors in Namibia

About 61% of the people in listed cities live in Windhoek, Rundu and Walvis Bay; buyers are concentrated in a few centres. Windhoek is both the capital and the largest listed city, with about 386,000 people, so the capital is also the biggest single market. The table lists the largest cities in Namibia with the climate stress that wears contactors fastest in each.

CityPeopleClimateWhat wears contactors first
Windhoek386,000hot and ariddust on contacts and blocked cooling
Rundu75,000hot and aridterminals loosening and parts running hot
Walvis Bay74,000hot and aridterminals loosening and parts running hot
Oshakati43,000hot and aridterminals loosening and parts running hot
Rehoboth34,000hot and ariddust on contacts and blocked cooling
Okahandja27,000hot and ariddust on contacts and blocked cooling

Time zone, sun and daylight in Namibia

Windhoek keeps UTC+2 all year.

At 22.6° S, Windhoek has about 10 h 45 min of daylight at the June solstice and about 13 h 31 min at the December solstice. The noon sun stands 44° above the horizon in June and 89° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

Size and settlement in Namibia

By land area Namibia is the 34th largest of the 241 places listed here, at roughly 825,418 km², a little larger than Pakistan (803,940 km²). Population density averages 3.0 people per km² across 2.4 million residents, which is sparsely settled and sparser than 97% of the other countries in this directory. With long distances between sites, a call-out for a missing part is costly, so keep a small stock of the common ratings. In population it sits close to the Gambia, which has about 2.3 million.

Where contactors are used in Namibia

Typical work in Namibia that needs contactors:

  • Compressor control in split and packaged air conditioners
  • Condenser fan switching
  • Lighting and general power switching in plant rooms
  • Chiller and air handling unit starter panels
  • Heat pump defrost and reversing controls

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing contactors for Namibia

  • Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
  • Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
  • Confirm the supply first: Namibia uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • For hot and arid conditions in Namibia, favour higher temperature ratings and some margin on every rated value.

Keeping contactors reliable in Namibia

  • Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.

Namibia lies in the southern hemisphere, where cooling demand usually peaks from November to March. Schedule inspections of contactors for September or October, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Signs of trouble

  • A compressor that will not start although the thermostat is calling for cooling

Approvals for contactors sold into Namibia

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Namibia, the local framework is NSI (Namibian Standards Institution) requirements, so match the datasheet to both and ask for any conformity documents your project needs.

Supply and delivery to Namibia

Cargo for Namibia usually arrives through Walvis Bay; tell us your preferred port or delivery address with your enquiry.

The local currency is the Dollar (NAD), so confirm the quotation currency and delivery terms before you order. The main languages are English, Afrikaans, German and Herero; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Contactors in Namibia: common questions

Why does my contactor buzz?

Buzzing usually means low coil voltage, a dirty or worn magnetic core or a loose connection. Measure the voltage at the coil while the unit is calling for cooling.

What voltage should contactors be rated for in Namibia?

With a 230 V, 50 Hz supply, Namibia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

Which standards apply to contactors in Namibia?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Namibia the local framework is NSI (Namibian Standards Institution) requirements; request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Namibia?

Sea freight into Namibia normally clears through ports such as Walvis Bay, with onward delivery by road; urgent parts can travel by air.

Which cities in Namibia can I order contactors for?

Every listed city is covered. The largest are Windhoek (386,000), Rundu (75,000), Walvis Bay (74,000), Swakopmund (53,000) and Oshakati (43,000). The country page lists the rest.

Do the neighbours of Namibia use the same mains supply?

Yes. All 4 listed neighbours (South Africa, Botswana, Zambia and Angola) run on a nominal 230 V at 50 Hz, the same as Namibia, so the electrical rating of a part does not usually change at the border.

What local time and daylight should I plan for in Namibia?

Windhoek keeps UTC+2 all year. At 22.6° S there are about 10 h 45 min of daylight in June and about 13 h 31 min in December.

More Klima products for Namibia

Contactors in cities across Namibia