Klima Contactors in Canada
Canada is a large national market in North America, and its capital is Ottawa. Most of the country has a continental climate, and conditions vary by region. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Contactors are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 7 models, each with a specification table; send an enquiry from Canada for a quotation.
- Capital
- Ottawa
- Population
- 37.1 million
- Area
- 9,984,670 km²
- Time zone
- UTC-5, moving to UTC-4 while daylight saving applies
- Climate
- Continental
- Supply
- 120/240 V, 60 Hz
- Main ports
- Vancouver, Montreal, Halifax
- Standards
- CSA / cUL listing and the Canadian Electrical Code
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Canada · Klima Contactors overview
Conditions in Canada that affect contactors
In Canada, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of contactors during each seasonal service.
Low temperatures make plastics brittle and slow some electrical parts; let cold contactors warm up before fitting where you can, and never force a terminal.
The supply in Canada is 120/240 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a contactor.
Where contactors are needed in Canada
The largest listed city is Toronto, not the capital: Ottawa is roughly 349 km to its north-east, and orders should name the right one. About 34% of the people in listed cities live in Toronto, Montreal and Calgary; no single city dominates the market. Climate decides how contactors age, and it changes from city to city in Canada: the last column shows what to expect.
| City | People | Climate | What wears contactors first |
|---|---|---|---|
| Toronto | 2.8 million | continental | brittle insulation and hard starting |
| Montreal | 1.8 million | continental | brittle insulation and hard starting |
| Calgary | 1.3 million | continental | brittle insulation and hard starting |
| Edmonton | 1 million | continental | brittle insulation and hard starting |
| Mississauga | 718,000 | continental | brittle insulation and hard starting |
| Vancouver | 662,000 | temperate | moisture on terminals and corrosion |
The sun and the clock in Canada
The clock in Ottawa follows UTC-5, moving to UTC-4 while daylight saving applies. The listed cities of Canada fall in 5 standard time zones, from UTC-8 to UTC-4, so a delivery cut-off depends on where the order is going.
Ottawa lies at 45.4° N, 75.7° W. Daylight lasts about 15 h 40 min at the June solstice and about 8 h 43 min in December, with a noon sun 68° and 21° high; the sun climbs high in summer, so shade and ventilation around outdoor units matter.
Voltage next door: Canada and its neighbours
Across the border, the United States also runs on a nominal 120/240 V at 60 Hz, so ratings carry over between Canada and its neighbour; the nameplate of the equipment still decides.
Jobs in Canada that call for contactors
In Canada, these are the jobs that most often call for contactors:
- Compressor control in split and packaged air conditioners
- Walk-in cold rooms and refrigerated display cases
- Heat pump defrost and reversing controls
- Pump and ventilation motor control
- Chiller and air handling unit starter panels
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Canada
- Check whether the control logic needs auxiliary NO or NC contacts for feedback.
- Pick the right pole count: 2-pole for single-phase units where both lines must break, 3-pole for three-phase compressors.
- Confirm the supply first: Canada uses 120/240 V at 60 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- For continental conditions in Canada, allow for wide seasonal temperature swings.
Care and maintenance in Canada
- Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.
Because Canada is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service contactors in April or May, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A buzzing or chattering contactor
Approvals for contactors sold into Canada
Klima contactors are specified against IEC 60947-4-1 (contactors and motor-starters). For import and installation in Canada, buyers also meet CSA / cUL listing and the Canadian Electrical Code. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.
Supply and delivery to Canada
Sea freight into Canada normally clears through ports such as Vancouver, Montreal and Halifax, with onward delivery by road; urgent parts can travel by air.
The local currency is the Dollar (CAD), so confirm the quotation currency and delivery terms before you order. The main languages are English, French and Inuktitut; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about contactors in Canada
How often should contactors be replaced?
There is no fixed interval. Replace them when the contacts show pitting or heat discolouration, or at the first sign of intermittent starting. Frequent cycling shortens life.
What voltage should contactors be rated for in Canada?
Equipment in Canada runs from 120/240 V at 60 Hz; make sure the contactor you choose carries the right voltage and frequency rating for 60 Hz operation.
Which standards apply to contactors in Canada?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Canada the local framework is CSA / cUL listing and the Canadian Electrical Code; request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Canada?
Cargo for Canada usually arrives through Vancouver, Montreal and Halifax; tell us your preferred port or delivery address with your enquiry.
Which cities in Canada can I order contactors for?
Every listed city is covered. The largest are Toronto (2.8 million), Montreal (1.8 million), Calgary (1.3 million), Ottawa (1 million) and Edmonton (1 million). The country page lists the rest.
What local time and daylight should I plan for in Canada?
Ottawa keeps UTC-5, moving to UTC-4 while daylight saving applies. At 45.4° N there are about 15 h 40 min of daylight in June and about 8 h 43 min in December.
Do the neighbours of Canada use the same mains supply?
Yes. Its only listed neighbour (the United States) runs on a nominal 120/240 V at 60 Hz, the same as Canada, so the electrical rating of a part does not usually change at the border.
More Klima products for Canada
- Klima Capacitors in Canada
- Klima Delay on Make Timer in Canada
- Klima Transformer for HVAC in Canada
- Klima Flux Powder (100 g & 250 g) in Canada
- Klima Condensate Pump in Canada
- Klima Pressure Switches (High & Low) in Canada