Klima Industries

Yemen: Klima Contactors

With about 28.5 million people, Yemen is a mid-sized market in Asia. Its capital is Sanaa. Most of the country has a highland climate, and conditions vary by region. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.

The main users of contactors in Yemen are offices, shops and malls as well as factories and workshops. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Yemen are welcome.

Capital
Sanaa
Population
28.5 million
Area
527,970 km²
Time zone
UTC+3 all year
Climate
Highland
Supply
230 V, 50 Hz
Main ports
Aden, Hodeidah
Standards
YSMO (Yemen Standardization, Metrology and Quality Control Organization) requirements

Klima Contactors models

All Klima products for Yemen · Klima Contactors overview

What Yemen demands of contactors

In Yemen, cooling demand is moderate, and refrigeration and process loads stay steady all year. Thinner air reduces convective cooling, so contactors in outdoor panels run warmer than the same part at sea level; derate where the datasheet advises it.

Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.

With a 230 V, 50 Hz supply, Yemen follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

Contactors across the cities of Yemen

Sanaa is both the capital and the largest listed city, with about 1.9 million people, so the capital is also the biggest single market. The two listed cities furthest apart, Al Hudaydah and Ghayl Ba Wazir, are about 689 km from each other in a straight line, so delivery to the far end of the country is a long road journey. The table lists the largest cities in Yemen with the climate stress that wears contactors fastest in each.

CityPeopleClimateWhat wears contactors first
Sanaa1.9 millionhighlandexpansion and contraction loosening joints
Aden1.1 millionhot and ariddust on contacts and blocked cooling
Taiz941,000hot and ariddust on contacts and blocked cooling
Ibb772,000hot and ariddust on contacts and blocked cooling
Mukalla595,000hot and ariddust on contacts and blocked cooling
Dhamar160,000hot and ariddust on contacts and blocked cooling

Local conditions differ across the 22 listed cities (21 hot and arid and 1 highland), and the right part depends on which city it is for.

Size and settlement in Yemen

By land area Yemen is the 50th largest of the 241 places listed here, at roughly 527,970 km², a little larger than Thailand (514,000 km²). Its 28.5 million people give an average of 54 per km². In this directory that is moderately settled, sparser than 64% of the other countries in this directory. Settlement clusters around the main cities with long gaps between them, so name the city or region when you order. Its population is similar to that of Venezuela (28.9 million).

Mains supply across the borders of Yemen

Yemen borders Saudi Arabia and Oman. Oman runs on 230 V at 50 Hz like Yemen; Saudi Arabia (127/220 V, 60 Hz) does not share it, so check the supply before a part crosses the border.

Typical uses of contactors in Yemen

In Yemen, these are the jobs that most often call for contactors:

  • Compressor control in split and packaged air conditioners
  • Heat pump defrost and reversing controls
  • Heater banks and electric reheat
  • Condenser fan switching
  • Chiller and air handling unit starter panels

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting contactors in Yemen

  • Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
  • Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
  • Confirm the supply first: Yemen uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • For highland conditions in Yemen, allow extra rating margin for thin air.

Care and maintenance in Yemen

  • Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.

Altitude moderates the heat in Yemen, but the load follows the dry and rainy seasons and the sun. Check contactors at the change of season and keep spares for peak periods. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • A compressor that will not start although the thermostat is calling for cooling

Approvals for contactors sold into Yemen

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Yemen, the local framework is YSMO (Yemen Standardization, Metrology and Quality Control Organization) requirements, so match the datasheet to both and ask for any conformity documents your project needs.

Supply and delivery to Yemen

Sea freight into Yemen normally clears through ports such as Aden and Hodeidah, with onward delivery by road; urgent parts can travel by air.

The local currency is the Rial (YER), so confirm the quotation currency and delivery terms before you order. The main languages are Arabic; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about contactors in Yemen

Can I replace a contactor with a higher amp rating?

Yes. A higher rated current is safe and usually longer lasting, provided the coil voltage, pole count and physical size suit the installation.

What voltage should contactors be rated for in Yemen?

Yemen supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Which standards apply to contactors in Yemen?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Yemen the local framework is YSMO (Yemen Standardization, Metrology and Quality Control Organization) requirements; request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Yemen?

Cargo for Yemen usually arrives through Aden and Hodeidah; tell us your preferred port or delivery address with your enquiry.

Which cities in Yemen can I order contactors for?

Every listed city is covered. The largest are Sanaa (1.9 million), Aden (1.1 million), Taiz (941,000), Ibb (772,000) and Al Hudaydah (735,000). The country page lists the rest.

Do the neighbours of Yemen use the same mains supply?

Partly. Oman runs on 230 V at 50 Hz, but Saudi Arabia (127/220 V, 60 Hz) differs, so check the supply before ordering for the other side.

What local time and daylight should I plan for in Yemen?

Sanaa keeps UTC+3 all year. At 15.4° N there are about 13 h 02 min of daylight in June and about 11 h 13 min in December.

More Klima products for Yemen

Contactors in cities across Yemen