Contactors supply in Greece

Greece is a mid-sized market in Europe, and its capital is Athens. The prevailing climate is Mediterranean, though conditions differ between regions. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.

The main users of contactors in Greece are offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Greece are welcome.

Capital
Athens
Population
10.7 million
Area
131,940 km²
Time zone
UTC+2, moving to UTC+3 while daylight saving applies
Climate
Mediterranean
Supply
230 V, 50 Hz
Main ports
Piraeus
Standards
CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations

Klima Contactors models

All Klima products for Greece · Klima Contactors overview

Contactors and the climate in Greece

In Greece, cooling demand peaks from late spring to early autumn. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.

Greece supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Cities that buy contactors in Greece

About 49% of the people in listed cities live in Athens, Thessaloniki and Patra; demand is shared between a few large centres and many smaller cities. The capital, Athens, is also the largest listed city (about 664,000 people), which keeps most large buyers in one place. These are the biggest listed cities in Greece; the last column names what to watch for in contactors there.

CityPeopleClimateWhat wears contactors first
Athens664,000Mediterraneanterminals loosening and parts running hot
Thessaloniki318,000Mediterraneanexpansion and contraction loosening joints
Patra168,000Mediterraneanterminals loosening and parts running hot
Irakleion137,000Mediterraneanterminals loosening and parts running hot
Trikala62,000Mediterraneanexpansion and contraction loosening joints
Chalkida59,000Mediterraneanexpansion and contraction loosening joints

Mains supply across the borders of Greece

Greece borders Albania, North Macedonia, Turkey and Bulgaria. All of them use a nominal 230 V at 50 Hz, the same as Greece, so an electrical rating that fits one side of the border fits the other.

How large is Greece, and how is it settled?

At roughly 131,940 km², Greece is the 97th largest of the 241 countries covered by this directory, a little larger than Nicaragua (129,494 km²). With 10.7 million residents the average density is 81 per km², so Greece counts as moderately settled, close to the middle of the directory for density. Settlement clusters around the main cities with long gaps between them, so name the city or region when you order. For scale, the Dominican Republic has a similar number of people (10.6 million).

Typical uses of contactors in Greece

In Greece, these are the jobs that most often call for contactors:

  • Compressor control in split and packaged air conditioners
  • Hotel fan coil and VRF outdoor unit panels
  • Heat pump defrost and reversing controls
  • Condenser fan switching
  • Walk-in cold rooms and refrigerated display cases

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing contactors for Greece

  • Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
  • Check whether the control logic needs auxiliary NO or NC contacts for feedback.
  • Confirm the supply first: Greece uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Greece that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.

Keeping contactors reliable in Greece

  • Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.

Greece lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of contactors for April or May, ahead of that peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Signs of trouble

  • A buzzing or chattering contactor

Approvals for contactors sold into Greece

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters); in Greece expect CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering contactors for Greece

Cargo for Greece usually arrives through Piraeus; tell us your preferred port or delivery address with your enquiry.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are Modern Greek, English and French; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about contactors in Greece

What does the number of poles mean?

A pole is one switched circuit. A 2-pole contactor breaks both line wires of a single-phase supply, while a 3-pole contactor breaks all three phases of a three-phase supply.

What voltage should contactors be rated for in Greece?

The mains supply in Greece is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to contactors in Greece?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Greece the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Greece?

Sea freight into Greece normally clears through ports such as Piraeus, with onward delivery by road; urgent parts can travel by air.

Which cities in Greece can I order contactors for?

Every listed city is covered. The largest are Athens (664,000), Thessaloniki (318,000), Patra (168,000), Larisa (147,000) and Irakleion (137,000). The country page lists the rest.

What local time and daylight should I plan for in Greece?

Athens keeps UTC+2, moving to UTC+3 while daylight saving applies. At 38.0° N there are about 14 h 48 min of daylight in June and about 9 h 31 min in December.

Do the neighbours of Greece use the same mains supply?

Yes. All 4 listed neighbours (Albania, North Macedonia, Turkey and Bulgaria) run on a nominal 230 V at 50 Hz, the same as Greece, so the electrical rating of a part does not usually change at the border.

More Klima products for Greece

Contactors in cities across Greece