Klima Contactors in Mauritius
Home to about 1.3 million people, Mauritius sits in Africa. Its capital is Port Louis. The climate across Mauritius is hot and humid tropical, with only modest differences from one place to another. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Contactors are bought here mainly for offices, shops and malls as well as homes and apartments. The range below has 7 models; send an enquiry with the model code and your delivery address in Mauritius.
- Capital
- Port Louis
- Population
- 1.3 million
- Area
- 2,040 km²
- Time zone
- UTC+4 all year
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
- Main ports
- Port Louis
- Standards
- MSB (Mauritius Standards Bureau) requirements
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Mauritius · Klima Contactors overview
Contactors and the climate in Mauritius
In Mauritius, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Mauritius supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Contactors across the cities of Mauritius
About 62% of the people in listed cities live in Port Louis, Vacoas and Beau Bassin-Rose Hill; a few centres do most of the buying. The capital, Port Louis, is also the largest listed city (about 155,000 people), which keeps most large buyers in one place. Climate decides how contactors age, and it changes from city to city in Mauritius: the last column shows what to expect.
| City | People | Climate | What wears contactors first |
|---|---|---|---|
| Port Louis | 155,000 | hot and humid tropical | moisture on terminals and corrosion |
| Vacoas | 115,000 | hot and humid tropical | terminals loosening and parts running hot |
| Beau Bassin-Rose Hill | 111,000 | hot and humid tropical | moisture on terminals and corrosion |
| Quatre Bornes | 77,000 | hot and humid tropical | moisture on terminals and corrosion |
| Goodlands | 21,000 | hot and humid tropical | terminals loosening and parts running hot |
| Centre de Flacq | 18,000 | hot and humid tropical | moisture on terminals and corrosion |
Every one of the 9 listed cities has a hot and humid tropical climate, which keeps the choice of parts consistent from city to city.
The sun and the clock in Mauritius
The clock in Port Louis follows UTC+4 all year.
Sunlight at 20.2° S (Port Louis): about 10 h 55 min of daylight in June, about 13 h 21 min in December, and a noon sun that reaches 46° in June and 87° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.
Jobs in Mauritius that call for contactors
In Mauritius, these are the jobs that most often call for contactors:
- Heat pump defrost and reversing controls
- Hotel fan coil and VRF outdoor unit panels
- Compressor control in split and packaged air conditioners
- Pump and ventilation motor control
- Heater banks and electric reheat
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 230 V Coil | 3 | 32 | 230 V AC |
| Klima 3-Pole Contactor 40 A, 230 V Coil | 3 | 40 | 230 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Mauritius
- Pick the right pole count: 2-pole for single-phase units where both lines must break, 3-pole for three-phase compressors.
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Confirm the supply first: Mauritius uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
- For hot and humid tropical conditions in Mauritius, favour sealed, corrosion-resistant construction.
Care and maintenance in Mauritius
- Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.
With little seasonal change in temperature, air conditioning in Mauritius works almost every day. Spread checks of contactors through the year instead of waiting for a peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A compressor that will not start although the thermostat is calling for cooling
Standards and paperwork for contactors in Mauritius
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Mauritius, the local framework is MSB (Mauritius Standards Bureau) requirements, so match the datasheet to both and ask for any conformity documents your project needs.
Supply and delivery to Mauritius
Cargo for Mauritius usually arrives through Port Louis; tell us your preferred port or delivery address with your enquiry.
The local currency is the Rupee (MUR), so confirm the quotation currency and delivery terms before you order. The main languages are English, Bhojpuri and French; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Contactors in Mauritius: common questions
What coil voltage should I choose?
Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.
What voltage should contactors be rated for in Mauritius?
The mains supply in Mauritius is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
Which standards apply to contactors in Mauritius?
Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Mauritius the local framework is MSB (Mauritius Standards Bureau) requirements; request the datasheet and conformity documents with your enquiry.
How are contactors delivered to Mauritius?
Sea freight into Mauritius normally clears through ports such as Port Louis, with onward delivery by road; urgent parts can travel by air.
Which cities in Mauritius can I order contactors for?
Every listed city is covered. The largest are Port Louis (155,000), Vacoas (115,000), Beau Bassin-Rose Hill (111,000), Curepipe (79,000) and Quatre Bornes (77,000). The country page lists the rest.
What local time and daylight should I plan for in Mauritius?
Port Louis keeps UTC+4 all year. At 20.2° S there are about 10 h 55 min of daylight in June and about 13 h 21 min in December.
More Klima products for Mauritius
- Klima Capacitors in Mauritius
- Klima Delay on Make Timer in Mauritius
- Klima Transformer for HVAC in Mauritius
- Klima Filter Driers in Mauritius
- Klima Cables (3 & 4 Core) in Mauritius
- Klima Pressure Switches (High & Low) in Mauritius