Klima Industries

Buying contactors in Guinea

With about 12.4 million people, Guinea is a mid-sized market in Africa. Its capital is Conakry. Most of the country has a hot and humid tropical climate, and conditions vary by region. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of contactors in Guinea are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Guinea are welcome.

Capital
Conakry
Population
12.4 million
Area
245,857 km²
Time zone
UTC+0 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
Conakry
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Contactors models

All Klima products for Guinea · Klima Contactors overview

Contactors and the climate in Guinea

In Guinea, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed contactors and keep control boxes closed with their gaskets intact.

Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Guinea supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Cities that buy contactors in Guinea

From Kamsar to Lola, the longest straight-line gap between listed cities is about 739 km; so delivery to the far end of the country is a long road journey. The three largest listed cities (Conakry, Camayenne and Nzerekore) hold about 68% of the people living in listed cities, which means buyers are concentrated in a few centres. These are the biggest listed cities in Guinea; the last column names what to watch for in contactors there.

CityPeopleClimateWhat wears contactors first
Conakry1.9 millionhot and humid tropicalterminals loosening and parts running hot
Camayenne1.9 millionhot and humid tropicalterminals loosening and parts running hot
Nzerekore226,000hot and humid tropicalmoisture on terminals and corrosion
Kankan221,000hot and humid tropicalterminals loosening and parts running hot
Maneah194,000hot and humid tropicalmoisture on terminals and corrosion
Kamsar113,000hot and humid tropicalmoisture on terminals and corrosion

Every one of the 22 listed cities has a hot and humid tropical climate, which keeps the choice of parts consistent from city to city.

The land and the people of Guinea

The directory puts Guinea at about 245,857 km², the 78th largest of its 241 countries, almost exactly the size of the United Kingdom (244,820 km²). Its 12.4 million people give an average of 50 per km². In this directory that is moderately settled, sparser than 67% of the other countries in this directory. People and businesses cluster around the main cities, so say which city or region the delivery is for. For scale, Rwanda has a similar number of people (12.3 million).

Time zone, sun and daylight in Guinea

The clock in Conakry follows UTC+0 all year.

Sunlight at 9.5° N (Conakry): about 12 h 41 min of daylight in June, about 11 h 34 min in December, and a noon sun that reaches 76° in June and 57° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Where contactors are used in Guinea

Contactors are most often specified in Guinea for:

  • Chiller and air handling unit starter panels
  • Heater banks and electric reheat
  • Lighting and general power switching in plant rooms
  • Condenser fan switching
  • Heat pump defrost and reversing controls

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC
Klima 3-Pole Contactor 32 A, 230 V Coil332230 V AC
Klima 3-Pole Contactor 40 A, 230 V Coil340230 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting contactors in Guinea

  • Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
  • Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
  • Confirm the supply first: Guinea uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Guinea that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Keeping contactors reliable in Guinea

  • Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.

With little seasonal change in temperature, air conditioning in Guinea works almost every day. Spread checks of contactors through the year instead of waiting for a peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Faults to watch for

  • A compressor that will not start although the thermostat is calling for cooling

Approvals for contactors sold into Guinea

Klima contactors are specified against IEC 60947-4-1 (contactors and motor-starters). For import and installation in Guinea, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Getting contactors to Guinea

Cargo for Guinea usually arrives through Conakry; tell us your preferred port or delivery address with your enquiry.

The local currency is the Franc (GNF), so confirm the quotation currency and delivery terms before you order. The main languages are French; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about contactors in Guinea

Is a contactor the same as a relay?

They work the same way, but contactors are built for higher currents and repeated switching of motor loads, whereas relays handle small control currents.

What voltage should contactors be rated for in Guinea?

The mains supply in Guinea is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to contactors in Guinea?

Klima contactors follow IEC 60947-4-1 (contactors and motor-starters). In Guinea the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are contactors delivered to Guinea?

Sea freight into Guinea normally clears through ports such as Conakry, with onward delivery by road; urgent parts can travel by air.

Which cities in Guinea can I order contactors for?

Every listed city is covered. The largest are Conakry (1.9 million), Camayenne (1.9 million), Nzerekore (226,000), Kankan (221,000) and Maneah (194,000). The country page lists the rest.

What local time and daylight should I plan for in Guinea?

Conakry keeps UTC+0 all year. At 9.5° N there are about 12 h 41 min of daylight in June and about 11 h 34 min in December.

Do the neighbours of Guinea use the same mains supply?

Partly. Senegal, Sierra Leone, Ivory Coast, Guinea-Bissau and Mali run on 230 V at 50 Hz, but Liberia (120 V, 60 Hz) differs, so check the supply before ordering for the other side.

More Klima products for Guinea

Contactors in cities across Guinea