Klima Cables (3 & 4 Core)

Interconnecting cable between an indoor and an outdoor unit carries mains power, earth and the signal or switching conductors. Three-core cable normally carries live, neutral and earth for a single-phase unit; four-core cable adds a conductor for communications, a switched line, or the third phase on small three-phase equipment.

Klima 3- and 4-core cables are listed by cross-sectional area in mm², conductor type and sheath so installers can match the cable to the unit's maximum current and the length of the run. Longer runs and higher currents need larger conductors to limit voltage drop and heating.

Klima Cables in 3-core and 4-core constructions supply power and control wiring for indoor and outdoor air conditioning units. Choose by conductor cross-section, core count and insulation so the cable carries the load and survives the installation.

Models

Related products

Supply notes by country

How cables are chosen and used in each country, with notes for its cities.

Key features

  • Core counts. 3-core and 4-core constructions for single-phase, split-system and small three-phase wiring.
  • Cross-sections. A graded range of conductor sizes in mm² for different current ratings and run lengths.
  • Flexible stranded copper. Stranded conductors are easier to route through conduit and to terminate at unit terminals.
  • PVC insulation and sheath. A general-purpose class for indoor and sheltered outdoor routes.
  • Coil packs. Pack lengths suited to installers, with colour-coded cores for faster, safer termination.

Where cables are used

  • Indoor-to-outdoor interconnecting cable for split ACs
  • Power supply to packaged and ducted units
  • Cold room evaporator and condensing unit wiring
  • Fan coil unit and VRF branch wiring
  • Control panels and sub-distribution boards
  • Pump, fan and compressor motor connections
  • Temporary and portable equipment feeds
  • CRAC and CRAH unit supply in data halls
  • Building refurbishment and retrofit work

How to choose cables

  • Size the conductor from the unit's maximum running current and the cable length, and check that voltage drop stays within the limit in your local wiring rules.
  • Use 4-core where the unit needs a communication or switched conductor, and 3-core for simple live-neutral-earth feeds.
  • Choose the insulation class for the route. Outdoor runs exposed to sunlight need UV-resistant sheathing or conduit protection.
  • Check core colours against local wiring colour codes before terminating.
  • Avoid splices inside walls; use terminal blocks in accessible enclosures.

Care and maintenance

  • Protect cable where it passes through walls and metal edges with grommets or sleeves.
  • Support outdoor runs with clips or conduit so the sheath does not chafe or sag.
  • Test insulation resistance before reusing existing runs in older installations.

Common faults

  • Discoloured or brittle sheathing near hot refrigerant lines
  • Warm cable or terminals under load
  • Intermittent unit shutdowns caused by damaged conductors

Questions about cables

What is the difference between 3-core and 4-core cable?

3-core cable normally carries live, neutral and earth. 4-core adds a fourth conductor for communication or a switched supply, or carries three live phases plus earth on small three-phase equipment.

Which cable size do I need for an air conditioner?

It depends on the unit's maximum current, the cable length and the installation method. Many residential split units use 1.5 mm² to 2.5 mm² conductors, but always follow the unit's installation manual and your local wiring rules.

Can I use PVC cable outdoors?

Yes where it is protected from direct sunlight and mechanical damage, for example inside conduit or trunking. Exposed runs benefit from UV-resistant cable or extra protection.

What does cross-sectional area mean?

It is the copper area of one conductor in square millimetres. A larger area carries more current with less heat and less voltage drop.

How long can the cable run be?

The limit comes from voltage drop. Longer runs need larger conductors, so ask your installer to calculate the drop for your load, voltage and length.

Should I use flexible or solid cable?

Flexible stranded cable suits equipment connections and conduit pulls. Solid conductor is common in fixed wiring but harder to terminate at unit terminals.