Klima Copper Coils & Tubes
Refrigerant pipework has to be clean, dry and leak-tight for decades. Copper is the standard material because it is strong, easy to bend and braze, and compatible with common refrigerants and oils. Soft-drawn coils let installers bend the pipe by hand or with a spring bender, while straight lengths suit plant rooms and long vertical risers.
Klima Copper Coils and Tubes are listed by size in inches and millimetres, wall thickness, temper and length. Pancake (level-wound) coils are convenient for split-system installations, and straight tube in hard temper is used where rigidity matters. Wall thickness matters too: higher-pressure refrigerants such as R410A need heavier walls than older R22 or R134a systems.
Klima Copper Coils and Tubes are the refrigerant-grade copper pipe used to join indoor and outdoor units and to build refrigeration circuits. The model list is organised by outside diameter, wall thickness and length so you can order exactly what the circuit needs.
Models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
Related products
Supply notes by country
How copper coils and tubes are chosen and used in each country, with notes for its cities.
- Afghanistan
- Aland Islands
- Albania
- Algeria
- American Samoa
- Andorra
- Angola
- Anguilla
- Antigua and Barbuda
- Argentina
- Armenia
- Aruba
- Australia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bermuda
- Bhutan
- Bolivia
- Bonaire, Saint Eustatius and Saba
- Bosnia and Herzegovina
- Botswana
- Brazil
- British Virgin Islands
- Brunei
- Bulgaria
- Burkina Faso
- Burundi
- Cambodia
- Cameroon
- Canada
- Cape Verde
- Cayman Islands
- Central African Republic
- Chad
- Chile
- China
- Christmas Island
- Cocos Islands
- Colombia
- Comoros
- Cook Islands
- Costa Rica
- Croatia
- Cuba
- Curacao
- Cyprus
- Czech Republic
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- DR Congo
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Eswatini
- Ethiopia
- Falkland Islands
- Faroe Islands
- Fiji
- Finland
- France
- French Guiana
- French Polynesia
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Gibraltar
- Greece
- Greenland
- Grenada
- Guadeloupe
- Guam
- Guatemala
- Guernsey
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Honduras
- Hong Kong
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Isle of Man
- Israel
- Italy
- Ivory Coast
- Jamaica
- Japan
- Jersey
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macau
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Martinique
- Mauritania
- Mauritius
- Mayotte
- Mexico
- Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Montserrat
- Morocco
- Mozambique
- Myanmar
- Namibia
- Nauru
- Nepal
- New Caledonia
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Niue
- Norfolk Island
- North Korea
- North Macedonia
- Northern Mariana Islands
- Norway
- Oman
- Pakistan
- Palau
- Palestine
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Pitcairn
- Poland
- Portugal
- Puerto Rico
- Qatar
- Republic of the Congo
- Reunion
- Romania
- Russia
- Rwanda
- Saint Barthelemy
- Saint Helena
- Saint Martin
- Saint Pierre and Miquelon
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Sint Maarten
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Korea
- South Sudan
- Spain
- Sri Lanka
- St Kitts and Nevis
- St Lucia
- St Vincent and the Grenadines
- Sudan
- Suriname
- Svalbard and Jan Mayen
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- The Netherlands
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Turks and Caicos Islands
- Tuvalu
- U.S. Virgin Islands
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Vatican City
- Venezuela
- Vietnam
- Wallis and Futuna
- Western Sahara
- Yemen
- Zambia
- Zimbabwe
Key features
- Outside diameters. A graded range of sizes from small branch lines up to larger suction-line diameters, in inch and millimetre sizes.
- Wall thicknesses. Options for R22, R134a and R404A duty as well as higher-pressure R410A and R32 systems.
- Coil formats. Soft-temper level-wound (pancake) coils for installers and straight lengths for fixed pipework.
- Clean and capped. Refrigeration-grade tube is supplied cleaned and sealed so it stays dry until it is used.
- Insulation pairing. Sizes line up with standard foam insulation sleeves.
Where copper coils and tubes are used
- Split-system liquid and suction lines
- VRF and multi-split branch piping
- Condensing unit to evaporator lines in cold rooms
- Chiller and package unit refrigerant circuits
- Heat pump refrigerant lines
- Display cabinets and ice machines
- Marine and offshore refrigeration
- Heat exchanger and coil repair
- Replacement coils and repair sections
How to choose copper coils and tubes
- Match outside diameter to the service connections on the indoor and outdoor units, and do not mix imperial and metric sizes without adaptors.
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- Use soft coils for bends and flare connections, and hard-drawn straight tube where the pipe must stay rigid.
- Order enough length for the full run plus waste for bends and brazing off-cuts.
- Pair liquid and suction lines with insulation of the correct bore and thickness.
Care and maintenance
- Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
- Bend with a proper bender; kinked tube restricts flow and fatigues at the crease.
Common faults
- Oil stains or frost at joints
- A system that loses charge slowly
- Restricted flow caused by kinks or oxide flakes
Questions about copper coils and tubes
Which copper tube is used for air conditioners?
Seamless refrigeration-grade (ACR) copper tube, cleaned and capped, is used for refrigerant lines. Common air conditioner sizes include 1/4, 3/8, 1/2, 5/8 and 3/4 inch outside diameters.
What wall thickness do I need for R410A?
R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.
What is the difference between a pancake coil and straight tube?
A pancake coil is soft-annealed tube wound flat in a level spiral for easy bending on site. Straight lengths are usually supplied in hard temper for rigid, fixed pipework.
How do I join copper tube?
By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.
Can I reuse old copper pipe?
Old pipe can be reused only if it is the right size and wall thickness, clean inside and pressure tested. Contaminated or oil-stained pipe is safer replaced.
How much pipe do I need?
Measure the route between the units, add 10 to 15 % for bends and trimming, and choose a coil or straight lengths that match the route to waste as little as possible.