Copper coils and tubes for Suriname
Home to about 576,000 people, Suriname sits in South America. Its capital is Paramaribo. The prevailing climate is hot and humid tropical, though conditions differ between regions. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Copper coils and tubes are bought here mainly for offices, shops and malls as well as factories and workshops. The Klima range includes 6 models, each with a specification table; send an enquiry from Suriname for a quotation.
- Capital
- Paramaribo
- Population
- 576,000
- Area
- 163,270 km²
- Time zone
- UTC-3 all year
- Climate
- Hot and humid tropical
- Supply
- 127 V, 60 Hz
- Main ports
- Paramaribo
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Suriname · Klima Copper Coils & Tubes overview
Conditions in Suriname that affect copper coils and tubes
In Suriname, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Mapping demand for copper coils and tubes in Suriname
Paramaribo, the capital, is the only city listed for Suriname, with about 224,000 people, so every enquiry from the country can be tied to one place. Parts for Suriname are best planned around Paramaribo, which has a hot and humid tropical climate. In Paramaribo, expect high head pressure and hot joints to show first on copper coils and tubes.
Time zone, sun and daylight in Suriname
The clock in Paramaribo follows UTC-3 all year.
Sunlight at 5.9° N (Paramaribo): about 12 h 28 min of daylight in June, about 11 h 47 min in December, and a noon sun that reaches 72° in June and 61° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat.
Size and settlement in Suriname
Suriname covers about 163,270 km², the 93rd largest of the 241 countries in this directory, almost exactly the size of Tunisia (163,610 km²). Its 576,000 people give an average of 3.5 per km². In this directory that is sparsely settled, sparser than 96% of the other countries in this directory. Sites can be a long way apart, so it is worth ordering a full set of spares for the season rather than one part at a time. Its population is similar to that of Luxembourg (608,000).
Jobs in Suriname that call for copper coils and tubes
Copper coils and tubes are most often specified in Suriname for:
- Split-system liquid and suction lines
- Heat pump refrigerant lines
- VRF and multi-split branch piping
- Replacement coils and repair sections
- Condensing unit to evaporator lines in cold rooms
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
| Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall | 3/4 in | 19.05 | 1.0 |
| Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall | 7/8 in | 22.2 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Suriname
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- Order enough length for the full run plus waste for bends and brazing off-cuts.
- Ask for the datasheet and the documents your project needs; in Suriname that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).
- For hot and humid tropical conditions in Suriname, favour sealed, corrosion-resistant construction.
Care and maintenance in Suriname
- Bend with a proper bender; kinked tube restricts flow and fatigues at the crease.
A tropical climate keeps cooling demand steady through the year in Suriname, so there is no quiet season. Schedule checks of copper coils and tubes around the main rainy-season changes and keep spares on hand. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Signs of trouble
- A system that loses charge slowly
Approvals for copper coils and tubes sold into Suriname
Two sets of rules apply to copper coils and tubes sold into Suriname: the product standard, EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning), and the local one, applicable national electrical-safety and import conformity rules (generally IEC-based). Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Getting copper coils and tubes to Suriname
Sea freight into Suriname normally clears through ports such as Paramaribo, with onward delivery by road; urgent parts can travel by air.
The local currency is the Dollar (SRD), so confirm the quotation currency and delivery terms before you order. The main languages are Dutch, English, Sranan Tongo and Caribbean Hindustani; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Suriname: common questions
How do I join copper tube?
By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.
How does the climate in Suriname affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
Which standards apply to copper coils and tubes in Suriname?
Klima copper coils and tubes follow EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning). In Suriname the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are copper coils and tubes delivered to Suriname?
Cargo for Suriname usually arrives through Paramaribo; tell us your preferred port or delivery address with your enquiry.
Which city in Suriname can I order copper coils and tubes for?
Paramaribo (224,000) is the one city listed for Suriname, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
What local time and daylight should I plan for in Suriname?
Paramaribo keeps UTC-3 all year. At 5.9° N there are about 12 h 28 min of daylight in June and about 11 h 47 min in December.
More Klima products for Suriname
- Klima Filter Driers in Suriname
- Klima Flux Powder (100 g & 250 g) in Suriname
- Klima Map Gas (Brazing & Welding) in Suriname
- Klima Pressure Switches (High & Low) in Suriname
- Klima Temperature Controllers in Suriname
- Klima Thermometers for HVAC in Suriname