Klima Industries

Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall

Refrigeration-grade soft copper coil, 1/2 in outside diameter with 0.8 mm wall, 15 m.

Klima Copper Coils & Tubes ยท Model KCU-12-08

About this copper tube

The 1/2 in (12.7 mm) coil is the common gas-line size for split systems in the range of about 1.5 to 2 tons, and a liquid-line size for larger systems. It has a 0.8 mm wall, so the bore is 11.1 mm: about 96.8 ml per metre, or roughly 1.45 litres in a 15 m coil, with some five and a half times the flow area of the 1/4 in coil. The copper is soft (annealed) and level-wound.

The gas line carries refrigerant vapour back to the compressor at low density, so its diameter affects pressure drop more than any other line. The manufacturer's table of line sizes gives the diameter for each model and for runs of different length; follow it, since a undersized gas line cuts capacity and can leave oil in the evaporator. On long vertical runs, check the manual for oil-return traps.

Specifications

SpecificationValue
ModelKCU-12-08
Size1/2 in
Outside diameter12.7 mm
Wall thickness0.8 mm
Length15 m
TemperSoft (annealed)
FormatLevel-wound coil

Where it fits

  • Gas line on 1.5 to 2 ton split systems with 1/2 in connections
  • Liquid line on larger packaged and multi-split systems
  • Suction lines on small refrigeration condensing units
  • Replacement of damaged sections in an existing line set

Fitting and checking

Bends in 1/2 in tube need a proper bender, because a hand bend easily kinks the wall. Keep every bend gentle, support the line so it cannot vibrate against a wall and wrap the insulation over any exposed length. If you braze, protect the equipment's valves from heat with a wet cloth or a heat-sink compound, and flow dry nitrogen through the line so that no scale forms inside.

Compared with the other copper coils and tubes

This model is one of 6 in Klima Copper Coils & Tubes; what changes from one to the next is size, outside diameter and wall thickness. Every model in the family has the same length (15 m), temper (Soft (annealed)) and format (Level-wound coil), so the choice comes down to the values above.

SpecificationThis modelAcross the range
Size1/2 in1/4 in / 3/8 in / 1/2 in / 5/8 in and 2 more
Outside diameter12.7 mm6.35 to 22.2 mm
Wall thickness0.8 mm0.8 to 1 mm

Ordered by outside diameter, this model is number 3 of 6: the next step down is Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall (9.52 mm) and the next step up is Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall (15.88 mm). Quote the model code KCU-12-08 when you enquire so that the right size is supplied.

Questions

Does this size match the 1.5 ton and 2 ton splits I install?

Many such systems use a 1/2 in gas line, but not all. The manufacturer's line-set table decides, because brand and model change the sizes.

Can I flare this tube instead of brazing it?

Yes, where the equipment has flare ports; use the correct flaring tool and torque. Brazing is the choice where a permanent joint without flare nuts is needed.

Selection, care and fault-finding notes for the whole family are on the Klima Copper Coils & Tubes page, and the contact page takes enquiries with the model code KCU-12-08. For background reading, see the guide Brazing refrigerant pipe: flux, filler rods and map gas.