Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall
Refrigeration-grade soft copper coil, 3/8 in outside diameter with 0.8 mm wall, 15 m.
Klima Copper Coils & Tubes ยท Model KCU-38-08
About this copper tube
At 3/8 in (9.52 mm) with a 0.8 mm wall, this coil is the size that crosses between liquid and gas duty. It serves as the liquid line on medium and large splits and as the gas (suction) line on smaller systems. The 7.92 mm bore has nearly three times the flow area of 1/4 in tube, about 49.3 ml per metre or roughly 740 ml per 15 m coil. It is soft (annealed) copper in a level-wound coil, ready for flaring or brazing.
The right size depends on the equipment: manufacturers specify the liquid and gas line diameters for each model, and the figures are not interchangeable. A line that is too small starves the system and raises the pressure drop; a line that is too large increases the refrigerant charge and can lead to oil return problems in a long run. Use the sizes in the equipment manual, not the nearest size in stock.
Specifications
| Specification | Value |
|---|---|
| Model | KCU-38-08 |
| Size | 3/8 in |
| Outside diameter | 9.52 mm |
| Wall thickness | 0.8 mm |
| Length | 15 m |
| Temper | Soft (annealed) |
| Format | Level-wound coil |
Where it fits
- Liquid line on medium and large split and multi-split systems
- Gas line on small split systems with 3/8 in service ports
- Line sets for condensing units on cold rooms and display cabinets
- Replacement runs where the original tube was damaged or corroded
Fitting and checking
Leave the ends capped until the tube is installed. Support horizontal runs at regular intervals so the tube cannot sag, insulate gas lines along their full length and seal the insulation at the joints. After brazing, pressure test with nitrogen and hold the test long enough to show a small leak. Pull a deep vacuum and confirm that it holds before releasing the refrigerant.
Compared with the other copper coils and tubes
This model is one of 6 in Klima Copper Coils & Tubes; what changes from one to the next is size, outside diameter and wall thickness. Every model in the family has the same length (15 m), temper (Soft (annealed)) and format (Level-wound coil), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Size | 3/8 in | 1/4 in / 3/8 in / 1/2 in / 5/8 in and 2 more |
| Outside diameter | 9.52 mm | 6.35 to 22.2 mm |
| Wall thickness | 0.8 mm | 0.8 to 1 mm |
Ordered by outside diameter, this model is number 2 of 6: the next step down is Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall (6.35 mm) and the next step up is Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall (12.7 mm). Quote the model code KCU-38-08 when you enquire so that the right size is supplied.
Questions
Can I use this tube for both liquid and gas lines?
Yes, if the equipment specification calls for 3/8 in on that line. The gas line must be insulated; the liquid line is insulated where it passes through hot spaces or where condensation would be a problem.
Is 0.8 mm enough for R410A at this size?
Many installers use 0.8 mm as the minimum for sizes up to 1/2 in on R410A systems, but the equipment manufacturer's requirement takes precedence.
Selection, care and fault-finding notes for the whole family are on the Klima Copper Coils & Tubes page, and the contact page takes enquiries with the model code KCU-38-08. For background reading, see the guide Brazing refrigerant pipe: flux, filler rods and map gas.