Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall
Refrigeration-grade soft copper coil, 3/4 in outside diameter with 1.0 mm wall, 15 m.
Klima Copper Coils & Tubes ยท Model KCU-34-10
About this copper tube
The 3/4 in (19.05 mm) coil has a 1.0 mm wall and a bore of 17.05 mm: about 228 ml per metre, or roughly 3.4 litres in a full 15 m coil, and nearly 13 times the flow area of 1/4 in tube. It is soft (annealed) level-wound copper for the larger suction and gas lines of systems of around 3 to 5 tons, and for refrigeration circuits where the manufacturer specifies a 3/4 in line.
Larger tube brings its own handling problems. A full coil is heavy, so unroll it on a flat floor and straighten it gradually rather than pulling it. Keep it clean: the more tube you handle, the more dust and moisture can enter the open end, so cap the ends whenever work stops, and never lay open tube on a dirty roof.
Specifications
| Specification | Value |
|---|---|
| Model | KCU-34-10 |
| Size | 3/4 in |
| Outside diameter | 19.05 mm |
| Wall thickness | 1.0 mm |
| Length | 15 m |
| Temper | Soft (annealed) |
| Format | Level-wound coil |
Where it fits
- Gas line on larger split and ducted systems
- Suction line on condensing units and rack circuits of medium size
- Long runs to rooftop plant where a bigger bore limits pressure drop
- Hot-gas lines in defrost circuits where the design calls for 3/4 in
Fitting and checking
Support the line every metre or so and allow for thermal movement where it runs between fixed points. Make bends with a proper tube bender and avoid reworking a bend, since each flex hardens the copper. After brazing, pressure test with nitrogen to the system's test pressure, hold it, then evacuate to a deep vacuum. A large line holds more moisture, so allow time for the vacuum to settle.
Compared with the other copper coils and tubes
The 6 models in Klima Copper Coils & Tubes differ mainly in size, outside diameter and wall thickness. Every model in the family has the same length (15 m), temper (Soft (annealed)) and format (Level-wound coil), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Size | 3/4 in | 1/4 in / 3/8 in / 1/2 in / 5/8 in and 2 more |
| Outside diameter | 19.05 mm | 6.35 to 22.2 mm |
| Wall thickness | 1.0 mm | 0.8 to 1 mm |
Ordered by outside diameter, this model is number 5 of 6: the next step down is Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall (15.88 mm) and the next step up is Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall (22.2 mm). Quote the model code KCU-34-10 when you enquire so that the right size is supplied.
Questions
Which is better for a long run, 5/8 in or 3/4 in?
The manufacturer's line-size table decides, because it accounts for capacity, length and lift. A larger line lowers pressure drop but adds refrigerant charge and may affect oil return.
Can I bend 3/4 in tube by hand?
Not safely. A spring or lever bender sized for the tube prevents kinking; a kinked tube restricts flow and may crack at the bend.
Selection, care and fault-finding notes for the whole family are on the Klima Copper Coils & Tubes page, and the contact page takes enquiries with the model code KCU-34-10. For background reading, see the guide Brazing refrigerant pipe: flux, filler rods and map gas.