Klima Industries

Buying copper coils and tubes in Jamaica

Home to about 2.9 million people, Jamaica sits in North America. Its capital is Kingston. The climate across Jamaica is hot and humid tropical, with only modest differences from one place to another. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of copper coils and tubes in Jamaica are offices, shops and malls, homes and apartments as well as hotels and restaurants. The Klima range includes 6 models, each with a specification table; send an enquiry from Jamaica for a quotation.

Capital
Kingston
Population
2.9 million
Area
10,991 km²
Time zone
UTC-5 all year
Climate
Hot and humid tropical
Supply
110 V, 50 Hz
Main ports
Kingston
Standards
BSJ (Bureau of Standards Jamaica) requirements

Klima Copper Coils & Tubes models

All Klima products for Jamaica · Klima Copper Coils & Tubes overview

Conditions in Jamaica that affect copper coils and tubes

In Jamaica, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.

Rooftop copper can already be hot to the touch before you light the torch; shade the work, keep copper coils and tubes cool and heat evenly to avoid overheating the joint.

Where copper coils and tubes are needed in Jamaica

From New Kingston to Savanna-la-Mar, the longest straight-line gap between listed cities is about 145 km; which keeps most road deliveries inside a day. About 86% of the people in listed cities live in Kingston, New Kingston and Spanish Town; a few centres do most of the buying. The table lists the largest cities in Jamaica with the climate stress that wears copper coils and tubes fastest in each.

CityPeopleClimateWhat wears copper coils and tubes first
Kingston938,000hot and humid tropicalmoisture entering the circuit and corrosion
New Kingston584,000hot and humid tropicalmoisture entering the circuit and corrosion
Spanish Town145,000hot and humid tropicalhigh head pressure and hot joints
Ocho Rios27,000hot and humid tropicalhigh head pressure and hot joints
Old Harbour26,000hot and humid tropicalhigh head pressure and hot joints
Linstead21,000hot and humid tropicalmoisture entering the circuit and corrosion

The sun and the clock in Jamaica

Kingston keeps UTC-5 all year.

Sunlight at 18.0° N (Kingston): about 13 h 12 min of daylight in June, about 11 h 03 min in December, and a noon sun that reaches 85° in June and 49° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

The land and the people of Jamaica

At roughly 10,991 km², Jamaica is the 75th smallest of the 241 countries covered by this directory, almost exactly the size of Kosovo (10,908 km²). Population density averages 267 people per km² across 2.9 million residents, which is densely settled and denser than 78% of the other countries in this directory. Most sites sit within reach of a city, so deliveries can usually be planned city by city. For scale, Albania has a similar number of people (2.9 million).

Typical uses of copper coils and tubes in Jamaica

Typical work in Jamaica that needs copper coils and tubes:

  • VRF and multi-split branch piping
  • Split-system liquid and suction lines
  • Heat pump refrigerant lines
  • Display cabinets and ice machines
  • Condensing unit to evaporator lines in cold rooms

Klima copper coils and tubes models

ModelSize (in)Outside diameter (mm)Wall thickness (mm)
Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall1/4 in6.350.8
Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall3/8 in9.520.8
Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall1/2 in12.70.8
Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall5/8 in15.881.0
Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall3/4 in19.051.0
Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall7/8 in22.21.0

See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.

How to pick copper coils and tubes for work in Jamaica

  • Use soft coils for bends and flare connections, and hard-drawn straight tube where the pipe must stay rigid.
  • Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
  • For hot and humid tropical conditions in Jamaica, favour sealed, corrosion-resistant construction.
  • Ask for the datasheet and the documents your project needs; in Jamaica that usually means BSJ (Bureau of Standards Jamaica) requirements.

Care and maintenance in Jamaica

  • Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.

With little seasonal change in temperature, air conditioning in Jamaica works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.

Faults to watch for

  • Restricted flow caused by kinks or oxide flakes

Standards and paperwork for copper coils and tubes in Jamaica

Klima copper coils and tubes follow EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning); in Jamaica expect BSJ (Bureau of Standards Jamaica) requirements as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Getting copper coils and tubes to Jamaica

Sea freight into Jamaica normally clears through ports such as Kingston, with onward delivery by road; urgent parts can travel by air.

The local currency is the Dollar (JMD), so confirm the quotation currency and delivery terms before you order. The main languages are English; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about copper coils and tubes in Jamaica

How do I join copper tube?

By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.

How does the climate in Jamaica affect copper coils and tubes?

Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.

Which standards apply to copper coils and tubes in Jamaica?

Klima copper coils and tubes follow EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning). In Jamaica the local framework is BSJ (Bureau of Standards Jamaica) requirements; request the datasheet and conformity documents with your enquiry.

How are copper coils and tubes delivered to Jamaica?

Cargo for Jamaica usually arrives through Kingston; tell us your preferred port or delivery address with your enquiry.

Which cities in Jamaica can I order copper coils and tubes for?

Every listed city is covered. The largest are Kingston (938,000), New Kingston (584,000), Spanish Town (145,000), Montego Bay (83,000) and Mandeville (47,000). The country page lists the rest.

What local time and daylight should I plan for in Jamaica?

Kingston keeps UTC-5 all year. At 18.0° N there are about 13 h 12 min of daylight in June and about 11 h 03 min in December.

More Klima products for Jamaica

Copper coils and tubes in cities across Jamaica