Klima Industries

Buying copper coils and tubes in the Netherlands

The Netherlands is a mid-sized market in Europe, and its capital is Amsterdam. The prevailing climate is temperate, though conditions differ between regions. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.

Copper coils and tubes are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in the Netherlands.

Capital
Amsterdam
Population
17.2 million
Area
41,526 km²
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
Climate
Temperate
Supply
230 V, 50 Hz
Main ports
Rotterdam
Standards
CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations

Klima Copper Coils & Tubes models

All Klima products for the Netherlands · Klima Copper Coils & Tubes overview

What the Netherlands demands of copper coils and tubes

In the Netherlands, cooling demand is seasonal, with short hot spells that stress equipment. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near copper coils and tubes for oil traces after the first hot and the first cold spells.

Flux powder absorbs moisture from humid air and clumps; keep copper coils and tubes in sealed tubs and bags, and mix fresh paste for each session.

Mapping demand for copper coils and tubes in the Netherlands

About 37% of the people in listed cities live in Rotterdam, Amsterdam and The Hague; demand is spread across many cities. The widest gap between listed cities runs from Groningen to Maastricht, about 270 km, so most deliveries inside the country stay within a day of road. These are the biggest listed cities in the Netherlands; the last column names what to watch for in copper coils and tubes there.

CityPeopleClimateWhat wears copper coils and tubes first
Rotterdam868,000temperatejoint fatigue from temperature swings
Amsterdam742,000temperatemoisture entering the circuit and corrosion
The Hague474,000temperatemoisture entering the circuit and corrosion
Groningen245,000temperatemoisture entering the circuit and corrosion
Eindhoven236,000temperatemoisture entering the circuit and corrosion
Nijmegen177,000temperatejoint fatigue from temperature swings

The Netherlands in numbers

At roughly 41,526 km², the Netherlands is the 106th smallest of the 241 countries covered by this directory, almost exactly the size of Switzerland (41,290 km²). About 17.2 million people live there, an average of 415 people per km², which makes it very densely settled, denser than 89% of the other countries in this directory. Sites are close together, so one delivery can often serve several customers in the same trip. In population it sits close to Guatemala, which has about 17.2 million.

The sun and the clock in the Netherlands

Amsterdam keeps UTC+1, moving to UTC+2 while daylight saving applies.

Sunlight at 52.4° N (Amsterdam): about 16 h 48 min of daylight in June, about 7 h 40 min in December, and a noon sun that reaches 61° in June and 14° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat.

Where copper coils and tubes are used in the Netherlands

In the Netherlands, these are the jobs that most often call for copper coils and tubes:

  • Split-system liquid and suction lines
  • VRF and multi-split branch piping
  • Condensing unit to evaporator lines in cold rooms
  • Chiller and package unit refrigerant circuits
  • Replacement coils and repair sections

Klima copper coils and tubes models

ModelSize (in)Outside diameter (mm)Wall thickness (mm)
Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall1/4 in6.350.8
Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall3/8 in9.520.8
Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall1/2 in12.70.8
Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall5/8 in15.881.0
Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall3/4 in19.051.0
Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall7/8 in22.21.0

See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.

How to pick copper coils and tubes for work in the Netherlands

  • Use soft coils for bends and flare connections, and hard-drawn straight tube where the pipe must stay rigid.
  • Pair liquid and suction lines with insulation of the correct bore and thickness.
  • For temperate conditions in the Netherlands, allow for wide seasonal temperature swings.
  • Ask for the datasheet and the documents your project needs; in the Netherlands that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.

Keeping copper coils and tubes reliable in the Netherlands

  • Bend with a proper bender; kinked tube restricts flow and fatigues at the crease.

In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check copper coils and tubes in the Netherlands. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.

Signs of trouble

  • Oil stains or frost at joints

Which standards apply to copper coils and tubes in the Netherlands

Klima copper coils and tubes follow EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning); in the Netherlands expect CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Ordering copper coils and tubes for the Netherlands

Sea freight into the Netherlands normally clears through ports such as Rotterdam, with onward delivery by road; urgent parts can travel by air.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are Dutch and Western Frisian; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Copper coils and tubes in the Netherlands: common questions

How much pipe do I need?

Measure the route between the units, add 10 to 15 % for bends and trimming, and choose a coil or straight lengths that match the route to waste as little as possible.

How does the climate in the Netherlands affect copper coils and tubes?

Wide temperature swings move rigid pipework; leave bends and clips that let the line flex, and check copper coils and tubes connections for slow leaks each season.

Which standards apply to copper coils and tubes in the Netherlands?

Klima copper coils and tubes follow EN 12735-1 and ASTM B280 (copper tube for refrigeration and air conditioning). In the Netherlands the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.

How are copper coils and tubes delivered to the Netherlands?

Cargo for the Netherlands usually arrives through Rotterdam; tell us your preferred port or delivery address with your enquiry.

Which cities in the Netherlands can I order copper coils and tubes for?

Every listed city is covered. The largest are Rotterdam (868,000), Amsterdam (742,000), The Hague (474,000), Utrecht (376,000) and Groningen (245,000). The country page lists the rest.

What local time and daylight should I plan for in the Netherlands?

Amsterdam keeps UTC+1, moving to UTC+2 while daylight saving applies. At 52.4° N there are about 16 h 48 min of daylight in June and about 7 h 40 min in December.

More Klima products for the Netherlands

Copper coils and tubes in cities across the Netherlands