Klima Drier Core 48-KL
Moisture is the enemy of every refrigeration circuit. Even small amounts of water react with refrigerant and oil to form acids that corrode copper, sludge the oil and freeze at the expansion device. A drier core packed with desiccant sits inside a service shell on the liquid line and removes this moisture and acid, while its filter block traps solid debris.
The Klima Drier Core 48-KL is designed for replaceable-core shells of the 48 series. Because only the core is replaced, service is quicker and cheaper than cutting out a sealed filter drier, and the shell stays in the system. Fit a new core whenever the circuit is opened, after a compressor change and after any burnout clean-up. Confirm shell dimensions and end-plate style on the model list before ordering.
Klima Drier Core 48-KL is a replaceable filter-drier core for shell-type liquid and suction line driers. The desiccant core removes moisture and acid and filters fine debris, protecting expansion valves and compressors.
Models
- Klima Drier Core 48-KL Shell series: 48 series, Desiccant: Molecular sieve, Refrigerants: R22, R134a, R404A, R407C, R410A
- Klima Drier Core 48-KL, Sieve and Alumina Shell series: 48 series, Desiccant: Molecular sieve and activated alumina, Refrigerants: R22, R134a, R404A, R407C, R410A
Related products
Supply notes by country
How drier cores are chosen and used in each country, with notes for its cities.
- Afghanistan
- Aland Islands
- Albania
- Algeria
- American Samoa
- Andorra
- Angola
- Anguilla
- Antigua and Barbuda
- Argentina
- Armenia
- Aruba
- Australia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bermuda
- Bhutan
- Bolivia
- Bonaire, Saint Eustatius and Saba
- Bosnia and Herzegovina
- Botswana
- Brazil
- British Virgin Islands
- Brunei
- Bulgaria
- Burkina Faso
- Burundi
- Cambodia
- Cameroon
- Canada
- Cape Verde
- Cayman Islands
- Central African Republic
- Chad
- Chile
- China
- Christmas Island
- Cocos Islands
- Colombia
- Comoros
- Cook Islands
- Costa Rica
- Croatia
- Cuba
- Curacao
- Cyprus
- Czech Republic
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- DR Congo
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Eswatini
- Ethiopia
- Falkland Islands
- Faroe Islands
- Fiji
- Finland
- France
- French Guiana
- French Polynesia
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Gibraltar
- Greece
- Greenland
- Grenada
- Guadeloupe
- Guam
- Guatemala
- Guernsey
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Honduras
- Hong Kong
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Isle of Man
- Israel
- Italy
- Ivory Coast
- Jamaica
- Japan
- Jersey
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macau
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Martinique
- Mauritania
- Mauritius
- Mayotte
- Mexico
- Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Montserrat
- Morocco
- Mozambique
- Myanmar
- Namibia
- Nauru
- Nepal
- New Caledonia
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Niue
- Norfolk Island
- North Korea
- North Macedonia
- Northern Mariana Islands
- Norway
- Oman
- Pakistan
- Palau
- Palestine
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Pitcairn
- Poland
- Portugal
- Puerto Rico
- Qatar
- Republic of the Congo
- Reunion
- Romania
- Russia
- Rwanda
- Saint Barthelemy
- Saint Helena
- Saint Martin
- Saint Pierre and Miquelon
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Sint Maarten
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Korea
- South Sudan
- Spain
- Sri Lanka
- St Kitts and Nevis
- St Lucia
- St Vincent and the Grenadines
- Sudan
- Suriname
- Svalbard and Jan Mayen
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- The Netherlands
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Turks and Caicos Islands
- Tuvalu
- U.S. Virgin Islands
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Vatican City
- Venezuela
- Vietnam
- Wallis and Futuna
- Western Sahara
- Yemen
- Zambia
- Zimbabwe
Key features
- Replaceable-core design. Change only the core while the shell stays brazed in place.
- Moisture and acid removal. Desiccant core absorbs water and neutralises acid in the liquid line.
- Filtration. Traps solid debris, scale and fine particles before they reach the expansion valve.
- Refrigerant coverage. Listed for common HFC refrigerants, with notes for R410A and R32 duty.
- Sealed packaging. Cores arrive sealed so they do not saturate with humidity before installation.
Where drier cores are used
- Commercial refrigeration liquid lines
- Large split and packaged AC systems with shell driers
- Chillers and process cooling
- Cold storage and supermarket racks
- Post-burnout compressor clean-up
- Marine and reefer container refrigeration
- Ice plants and bottling lines
- Heat pump liquid lines
- Dairy and brewery cooling
How to choose drier cores
- Confirm the shell series and end-plate dimensions; the core must seat correctly against the gasket and spring.
- Match the desiccant to the job: molecular sieve for general moisture, with activated alumina added for acid after a burnout.
- Replace the core whenever the system is opened for service.
- Use a new gasket and keep the core sealed until the shell is open.
- Check pressure drop across the drier if performance falls after fitting.
Care and maintenance
- Never reuse a core; once exposed to air it starts absorbing humidity.
- Evacuate the system to a deep vacuum after the shell is closed, then charge by weight.
- Record the date of the core change on the service label.
Common faults
- Bubbles in the sight glass despite a full charge
- A cold section or frost on the drier body, which signals a restriction
- Expansion valve icing caused by moisture
Questions about drier cores
What does a drier core do?
It absorbs moisture and acid and filters solid particles from the refrigerant, which protects the expansion valve, the compressor and the oil.
When should I replace the drier core?
Whenever the system is opened, after a compressor replacement and after any burnout. Replace it too if the moisture indicator shows wet or there is a pressure drop across the drier.
What is the difference between a drier core and a filter drier?
A filter drier is a sealed, brazed-in shell with the desiccant inside. A replaceable-core system has a service shell with a removable core, so only the core is changed.
Can I use a drier core with R410A or R32?
Choose a core listed for the refrigerant in use and check pressure ratings, because higher-pressure refrigerants need compatible shells and cores.
How do I know which core fits my shell?
Compare the shell series, core length and end-plate style with the model list. If in doubt, send the shell nameplate to our team.
How long can a drier core be stored?
Keep the core sealed in its original packaging. Once the seal is broken, install it immediately or discard it.