Klima Freezer Thermostat, Capillary
Freezer thermostat for -35 to -5 °C control.
Klima Thermostats · Model KTS-Z35
About this thermostat
The KTS-Z35 is the freezer version of the capillary thermostat: a dial range of -35 to -5 °C, a 10 A contact switching 230 V AC and a bracket mount. The range is the point. A thermostat is easiest to set accurately near the middle of its scale, and a freezer holding -18 °C sits 17 K above the bottom of this range and 13 K below the top. On the fridge model, whose scale runs from -25 to +15 °C, the same set point would sit just 7 K from the cold end.
A freezer thermostat has to hold the cabinet through door openings and fresh loads. Its differential, the gap between cut-out and cut-in, sets how long the compressor rests between runs: a wide gap means longer cycles and fewer starts but a larger swing in product temperature, while a narrow gap gives a steadier cabinet and more starts. The product data does not list the differential, so when matching a replacement, compare it with the thermostat you are removing. The 10 A contact is a ceiling of about 2.3 kVA at 230 V for a resistive load, and a compressor's start current is higher than its running current.
Specifications
| Specification | Value |
|---|---|
| Model | KTS-Z35 |
| Type | Freezer thermostat |
| Temperature range | -35 to -5 °C |
| Supply | Switching 230 V AC |
| Output | Contact, 10 A |
| Sensor | Capillary |
| Connectivity | None |
| Mounting | Bracket |
| Display | Dial |
Where it fits
- Replacing a failed thermostat in a chest or upright freezer
- Display freezers and ice-cream cabinets in shops
- Small freezer cabinets in kitchens and food stores
- Equipment with a bracket-mounted thermostat and capillary sensing
Fitting and checking
Isolate the supply. Fit the bulb in the same place as the old one, firmly in contact with the point it senses, and keep the capillary clear of the compressor and condenser pipes, which would heat it and distort the reading. Do not kink or crush the tube. Let the freezer pull down fully, then leave a reference thermometer in the cabinet for an hour before you judge the dial setting.
Compared with the other thermostats
The 4 models in Klima Thermostats differ mainly in type, temperature range and supply.
| Specification | This model | Across the range |
|---|---|---|
| Type | Freezer thermostat | WiFi room thermostat / Fan coil thermostat / Fridge thermostat / Freezer thermostat |
| Temperature range | -35 to -5 °C | 5 to 35 / 10 to 30 / -25 to +15 / -35 to -5 |
| Supply | Switching 230 V AC | 230 V AC / Switching 230 V AC |
| Output | Contact, 10 A | Relay, 5 A / 3 fan speeds and valve output / Contact, 10 A |
| Sensor | Capillary | Built-in / Capillary |
The closest alternative in the range is Klima Fridge Thermostat, Capillary, which shares 6 of the 8 listed specifications and differs in type and temperature range. Quote the model code KTS-Z35 when you enquire.
Questions
Why not use the fridge thermostat in a freezer?
It can work if its range reaches your set point, but the freezer model's scale puts -18 °C near the middle of the dial and covers settings colder than -25 °C, which the fridge model cannot reach.
Does -35 °C on the dial mean the cabinet will reach -35 °C?
Not by itself. That is the limit of the thermostat's range. The cabinet reaches it only if the refrigeration system can pull that low.
Selection, care and fault-finding notes for the whole family are on the Klima Thermostats page, and the contact page takes enquiries with the model code KTS-Z35.