Klima Fridge Thermostat, Capillary
Fridge thermostat for -25 to +15 °C control.
Klima Thermostats · Model KTS-R15
About this thermostat
A capillary thermostat has no electronics. A sealed bulb on a thin tube, the capillary, senses temperature, and the pressure change inside moves a bellows that opens and closes a contact. The KTS-R15 is the fridge model: a dial setting range of -25 to +15 °C, a 10 A contact switching 230 V AC and a bracket mount. A fridge holding +4 °C sits 29 K above the bottom of that scale and 11 K below the top, in the upper part of the dial where it is easy to set.
Where the bulb is fixed decides what the thermostat controls. In many fridges it is clipped to the evaporator, so the thermostat follows the coil temperature and lets the coil warm and defrost during each off cycle; in others it sits in the cabinet air and follows the food space. Put the new bulb where the old one was. The 10 A rating is a ceiling of about 2.3 kVA at 230 V for a resistive load, and a compressor draws several times its running current when it starts, so check its nameplate before you wire one directly through the contact.
Specifications
| Specification | Value |
|---|---|
| Model | KTS-R15 |
| Type | Fridge thermostat |
| Temperature range | -25 to +15 °C |
| Supply | Switching 230 V AC |
| Output | Contact, 10 A |
| Sensor | Capillary |
| Connectivity | None |
| Mounting | Bracket |
| Display | Dial |
Where it fits
- Replacing a failed thermostat in a fridge, bottle cooler or display chiller
- Cabinets where the bulb is clipped to the evaporator or placed in the air stream
- Equipment that needs only a dial and a contact, with no supply to a controller
- Loads switched at 230 V AC within the 10 A contact rating
Fitting and checking
Isolate the supply and fix the thermostat on its bracket where the dial can be reached. Clip the bulb firmly in the position the old one occupied, so that it is in full contact with what it senses, and coil any spare capillary loosely, away from sharp edges and hot pipes. Never kink, cut or crush the capillary: a damaged one loses its charge and the thermostat stops switching. Turn the dial from warm to cold and listen for the contact to click, then check the cabinet with a reference thermometer after pull-down.
Compared with the other thermostats
Across the 4 models in Klima Thermostats, the values that vary are type, temperature range and supply.
| Specification | This model | Across the range |
|---|---|---|
| Type | Fridge thermostat | WiFi room thermostat / Fan coil thermostat / Fridge thermostat / Freezer thermostat |
| Temperature range | -25 to +15 °C | 5 to 35 / 10 to 30 / -25 to +15 / -35 to -5 |
| Supply | Switching 230 V AC | 230 V AC / Switching 230 V AC |
| Output | Contact, 10 A | Relay, 5 A / 3 fan speeds and valve output / Contact, 10 A |
| Sensor | Capillary | Built-in / Capillary |
The closest alternative in the range is Klima Freezer Thermostat, Capillary, which shares 6 of the 8 listed specifications and differs in type and temperature range. Quote the model code KTS-R15 when you enquire.
Questions
Can I use it in a freezer?
Only if the freezer set point is within -25 to +15 °C. A freezer at -18 °C sits only 7 K from the cold end of this dial, so the freezer model with its -35 to -5 °C range is the better fit.
Do the dial marks show the exact temperature?
No, they are a guide. Check the cabinet with a reference thermometer and adjust the dial until it holds the temperature you need.
Selection, care and fault-finding notes for the whole family are on the Klima Thermostats page, and the contact page takes enquiries with the model code KTS-R15.