Klima Industries

Klima Digital Cold Room Controller with Defrost

Digital controller with 2 relay outputs on 230 V AC.

Klima Temperature Controllers · Model KTC-2

About this temperature controller

A cold room needs more than a thermostat: the evaporator ices up and must be defrosted at intervals, or the airflow falls and the room stops cooling. This digital controller has two relays, one to run the compressor from the room temperature and one for the defrost, an NTC probe over -50 to 99 °C, an LED display, a 230 V AC supply and a panel mount. Its accuracy is ±1 °C.

The second relay is the defrost output: it can switch the contactor of a defrost heater or a hot-gas valve, depending on the plant, and the controller times the defrost and the return to cooling. Check the manual for the parameters, which usually include the interval between defrosts and their length. Use the relays to drive contactors and solenoids within their ratings, and not the motor current of a large compressor.

Specifications

SpecificationValue
ModelKTC-2
Supply230 V AC
Control range-50 to 99 °C
SensorNTC probe
Relay outputs2
Accuracy±1 °C
DisplayLED
MountingPanel

Where it fits

  • Walk-in cold rooms and freezer rooms with electric or hot-gas defrost
  • Display cabinets and reach-in freezers with a defrost heater
  • Cooling plant in shops, kitchens and food stores
  • Replacement for a mechanical thermostat and a separate defrost timer

Fitting and checking

Fit the room probe in the air return, away from the door and the evaporator outlet. Set the room temperature and the differential, then the defrost interval and length. Run a defrost by hand to see that the heater or valve works and that the compressor resumes afterwards.

Compared with the other temperature controllers

The 3 models in Klima Temperature Controllers differ mainly in supply and relay outputs. Every model in the family has the same control range (-50 to 99 °C), sensor (NTC probe), accuracy (±1 °C) and display (LED), so the choice comes down to the values above.

SpecificationThis modelAcross the range
Supply230 V AC230 V AC / 12 V DC
Relay outputs21 to 2

This is the largest model in the range by relay outputs. The next step down is Klima Digital Temperature Controller, 1 Relay (1). Quote the model code KTC-2 when you enquire so that the right size is supplied.

Questions

Why does a cold room need a defrost cycle?

Frost builds up on the evaporator and blocks airflow. A timed or temperature-ended defrost melts it, so the room keeps its temperature.

How often should the room defrost?

It depends on the room's temperature, door use and humidity. Start with the plant maker's recommendation and adjust according to how much ice forms.

Selection, care and fault-finding notes for the whole family are on the Klima Temperature Controllers page, and the contact page takes enquiries with the model code KTC-2. For background reading, see the guide Superheat and subcooling: measuring with the right thermometer.