Klima Digital Temperature Controller, 1 Relay
Digital controller with 1 relay output on 230 V AC.
Klima Temperature Controllers · Model KTC-1
About this temperature controller
The KTC-1 is a single-relay digital temperature controller: it reads an NTC probe over the range of -50 to 99 °C, shows the temperature on an LED display and switches its relay to hold a set point. It runs on 230 V AC, has an accuracy of ±1 °C and mounts in a panel. With one output it handles one job, such as cooling a cabinet, heating a cabinet or running a fan, which makes it the simple, general-purpose model in the family.
A relay in a controller is a signalling device and should not carry a compressor directly: use it to energise a contactor coil, and let the contactor carry the motor current. For stable control, put the probe where it sees the temperature that matters, such as the return air in a cabinet, and not on a coil or in a draught. A differential, which is the gap between switching on and off, stops the output from chattering around the set point.
Specifications
| Specification | Value |
|---|---|
| Model | KTC-1 |
| Supply | 230 V AC |
| Control range | -50 to 99 °C |
| Sensor | NTC probe |
| Relay outputs | 1 |
| Accuracy | ±1 °C |
| Display | LED |
| Mounting | Panel |
Where it fits
- Cooling control of display cabinets, bottle coolers and small cold rooms
- Heating control of enclosures, trays and anti-condensation heaters
- Fan control by temperature in panels and plant cabinets
- Replacement of a mechanical thermostat with an accurate digital one
Fitting and checking
Cut the panel opening to the controller's size, wire the 230 V supply, the probe and the relay output following the diagram, and fit the output to a contactor or a small load within the relay rating. Set the set point and the differential, and check the reading against a reference thermometer: the ±1 °C accuracy means the display can be a degree off the true temperature, so allow for that when food safety matters.
Compared with the other temperature controllers
Across the 3 models in Klima Temperature Controllers, the values that vary are supply and relay outputs. Every model in the family has the same control range (-50 to 99 °C), sensor (NTC probe), accuracy (±1 °C) and display (LED), so the choice comes down to the values above.
| Specification | This model | Across the range |
|---|---|---|
| Supply | 230 V AC | 230 V AC / 12 V DC |
| Relay outputs | 1 | 1 to 2 |
This is the smallest model in the range by relay outputs. The next step up is Klima Digital Cold Room Controller with Defrost (2). Quote the model code KTC-1 when you enquire so that the right size is supplied.
Questions
Can this controller defrost an evaporator?
It has one relay, so it controls one output. For cooling with a separate defrost output, choose the two-relay cold-room controller.
Where should the probe go?
In the air stream or product area you want to control, away from direct draughts, the evaporator coil and heat sources, and with the cable clipped so it cannot move.
Selection, care and fault-finding notes for the whole family are on the Klima Temperature Controllers page, and the contact page takes enquiries with the model code KTC-1. For background reading, see the guide Superheat and subcooling: measuring with the right thermometer.