Klima Digital Probe Thermometer
Digital probe thermometer for air, liquids and coil checks.
Klima Thermometers for HVAC · Model KTH-P1
About this thermometer
The KTH-P1 is a battery-powered digital probe thermometer for the readings a service technician takes most often: supply and return air, liquids such as chilled water and condensate, and spot checks on coils. It reads from -50 to 300 °C with an accuracy of ±1 °C, through a stainless probe.
The classic use is the temperature split across an evaporator coil, which shows whether the unit is moving heat. Take the return and supply readings in the same way and close together in time. With ±1 °C on each reading, the difference can be wrong by up to 2 K in the worst case, so a measured split of 8 K should be read as somewhere between 6 and 10 K. That is good enough to see that a coil is working or has stopped. For work where a fraction of a degree matters, such as superheat on a refrigerant line, the pipe clamp thermometer with its ±0.5 °C accuracy is the better tool.
Specifications
| Specification | Value |
|---|---|
| Model | KTH-P1 |
| Type | Digital probe |
| Range | -50 to 300 °C |
| Accuracy | ±1 °C |
| Probe / sensor | Stainless probe |
| Power | Battery |
| Typical use | Air, liquids and coil checks |
Where it fits
- Return and supply air readings to find the split across a coil
- Chilled water, condensate and other liquids checked during a service call
- Spot checks of coil and plate temperatures
- Comparing two points in a plant room, such as before and after a valve or filter
Fitting and checking
Check the battery before a job, since a weak battery gives drifting or blank readings. Put the probe in the air stream or liquid and wait until the reading stops changing, which can take a minute in still air. Keep the probe away from live terminals, because the stainless probe conducts. A slush of crushed ice and clean water is a quick accuracy check: the reading should be within ±1 °C of 0 °C.
Compared with the other HVAC thermometers
The 3 models in Klima Thermometers for HVAC differ mainly in type, range and accuracy.
| Specification | This model | Across the range |
|---|---|---|
| Type | Digital probe | Digital probe / Pipe clamp / Dial |
| Range | -50 to 300 °C | -50 to 300 / -40 to 120 / -40 to 60 |
| Accuracy | ±1 °C | ±1 °C / ±0.5 °C / ±2 °C |
| Probe / sensor | Stainless probe | Stainless probe / Clamp sensor / Stem |
| Power | Battery | Battery / None |
The closest alternative in the range is Klima Pipe Clamp Thermometer, which shares 1 of the 7 listed specifications and differs in type, range and accuracy. Quote the model code KTH-P1 when you enquire.
Questions
How accurate is it?
±1 °C across its -50 to 300 °C range. Where you need ±0.5 °C, as for superheat work, choose the clamp model.
Can I use it on a refrigerant line?
Taped to the pipe and insulated, yes, but the clamp thermometer is made for this and holds better contact with the pipe wall.
Selection, care and fault-finding notes for the whole family are on the Klima Thermometers for HVAC page, and the contact page takes enquiries with the model code KTH-P1. For background reading, see the guide Superheat and subcooling: measuring with the right thermometer.