Klima Pipe Clamp Thermometer
Pipe clamp thermometer for refrigerant line temperature.
Klima Thermometers for HVAC · Model KTH-C1
About this thermometer
The KTH-C1 is a battery-powered pipe clamp thermometer for refrigerant line temperature. It reads from -40 to 120 °C with an accuracy of ±0.5 °C, the tightest of the three Klima thermometers. A clamp holds its sensor against the pipe wall, which gives a more repeatable reading than a probe that is held or taped on.
Accuracy matters most for superheat, the amount by which suction vapour is hotter than its saturation temperature, which is how technicians judge charge and expansion valve setting. The line temperature is read at the evaporator outlet and the saturation temperature comes from the suction pressure on the gauges. Against an example target of 7 K superheat, a thermometer error of ±0.5 °C is about ±7 % of the target, ±1 °C is about ±14 % and ±2 °C about ±29 %, before the gauge reading adds its own error. That spread is why the clamp model has the tightest tolerance in the range.
Specifications
| Specification | Value |
|---|---|
| Model | KTH-C1 |
| Type | Pipe clamp |
| Range | -40 to 120 °C |
| Accuracy | ±0.5 °C |
| Probe / sensor | Clamp sensor |
| Power | Battery |
| Typical use | Refrigerant line temperature |
Where it fits
- Superheat and subcooling checks on split systems and refrigeration circuits
- Suction and liquid line temperature checks
- Comparing line temperature before and after a drier, valve or coil
- Commissioning records that need a repeatable reading
Fitting and checking
Clean the pipe to bare metal at the measuring point, clamp the sensor on a straight section away from bends and cover the clamp with pipe insulation, so that the surrounding air does not pull the reading toward room temperature. Wait for the reading to settle. Keep it off hot lines near the top of the 120 °C range: a discharge line on a loaded system can approach it and a fault can exceed it.
Compared with the other HVAC thermometers
Across the 3 models in Klima Thermometers for HVAC, the values that vary are type, range and accuracy.
| Specification | This model | Across the range |
|---|---|---|
| Type | Pipe clamp | Digital probe / Pipe clamp / Dial |
| Range | -40 to 120 °C | -50 to 300 / -40 to 120 / -40 to 60 |
| Accuracy | ±0.5 °C | ±1 °C / ±0.5 °C / ±2 °C |
| Probe / sensor | Clamp sensor | Stainless probe / Clamp sensor / Stem |
| Power | Battery | Battery / None |
The closest alternative in the range is Klima Digital Probe Thermometer, which shares 1 of the 7 listed specifications and differs in type, range and accuracy. Quote the model code KTH-C1 when you enquire.
Questions
How does it differ from the probe thermometer?
The clamp reads -40 to 120 °C to ±0.5 °C and holds contact with the pipe; the probe model covers -50 to 300 °C to ±1 °C and suits air and liquids.
Why insulate over the clamp?
Air around the clamp is warmer or cooler than the pipe, and heat flowing to or from the sensor pulls the reading toward the air temperature. Insulation reduces that error.