Klima Industries

Temperature controllers for Reunion

With about 777,000 people, Reunion is a smaller national market in Africa. Its capital is Saint-Denis. The climate across Reunion is hot and humid tropical, with only modest differences from one place to another. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of temperature controllers in Reunion are offices, shops and malls as well as factories and workshops. The range below has 3 models; send an enquiry with the model code and your delivery address in Reunion.

Capital
Saint-Denis
Population
777,000
Area
2,517 km²
Time zone
UTC+4 all year
Climate
Hot and humid tropical
Supply
230 V, 50 Hz
Main ports
Le Port
Standards
applicable national electrical-safety and import conformity rules (generally IEC-based)

Klima Temperature Controllers models

All Klima products for Reunion · Klima Temperature Controllers overview

Conditions in Reunion that affect temperature controllers

In Reunion, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit temperature controllers with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

In very hot weather a badly placed control keeps the compressor running; mount temperature controllers out of direct sun and away from heat sources.

The mains supply in Reunion is 230 V, 50 Hz. Match temperature controllers to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Cities that buy temperature controllers in Reunion

About 49% of the people in listed cities live in Saint-Denis, Saint-Paul and Saint-Pierre; demand is shared between a few large centres and many smaller cities. Saint-Denis is both the capital and the largest listed city, with about 155,000 people, so the capital is also the biggest single market. The table lists the largest cities in Reunion with the climate stress that wears temperature controllers fastest in each.

CityPeopleClimateWhat wears temperature controllers first
Saint-Denis155,000hot and humid tropicalcondensation inside enclosures
Saint-Paul105,000hot and humid tropicalcondensation inside enclosures
Saint-Pierre84,000hot and humid tropicalcondensation inside enclosures
Saint-Louis54,000hot and humid tropicalcondensation inside enclosures
Saint-Joseph39,000hot and humid tropicalsensor drift and setpoints creeping
Saint-Benoit37,000hot and humid tropicalcondensation inside enclosures

How large is Reunion, and how is it settled?

Reunion covers about 2,517 km², the 63rd smallest of the 241 countries in this directory, a little smaller than Luxembourg (2,586 km²). About 777,000 people live there, an average of 309 people per km², which makes it densely settled, denser than 83% of the other countries in this directory. With so little land, distances inside the country are short, but an enquiry should still name the city or island for delivery. In population it sits close to Guyana, which has about 779,000.

Jobs in Reunion that call for temperature controllers

In Reunion, these are the jobs that most often call for temperature controllers:

  • Cold rooms and freezer rooms
  • Pharmacy and laboratory refrigerators
  • Process chillers and water temperature control
  • Incubators, brooders and growing rooms
  • Food-processing and bakery equipment

Klima temperature controllers models

ModelSupply (V)Control range (°C)Sensor
Klima Digital Temperature Controller, 1 Relay230 V AC-50 to 99NTC probe
Klima Digital Cold Room Controller with Defrost230 V AC-50 to 99NTC probe
Klima Digital Temperature Controller, 12 V12 V DC-50 to 99NTC probe

See the full Klima Temperature Controllers range for specifications, standards and a plain-language guide to choosing the right part.

Selecting temperature controllers in Reunion

  • Look for the compressor-delay and alarm features your standards or customers require.
  • Choose the control range and sensor to suit the application: low-temperature probes for freezers, higher ranges for heating processes.
  • Confirm the supply first: Reunion uses 230 V at 50 Hz, so check the voltage and frequency rating of temperature controllers against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Reunion that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Care and maintenance in Reunion

  • Keep probe cables away from power cables to avoid electrical noise.

A tropical climate keeps cooling demand steady through the year in Reunion, so there is no quiet season. Schedule checks of temperature controllers around the main rainy-season changes and keep spares on hand. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A compressor that short-cycles or fails to stop

Which standards apply to temperature controllers in Reunion

Two sets of rules apply to temperature controllers sold into Reunion: the product standard, IEC 60730-1 and IEC 60730-2-9 (temperature sensing controls), and the local one, applicable national electrical-safety and import conformity rules (generally IEC-based). Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.

Getting temperature controllers to Reunion

Cargo for Reunion usually arrives through Le Port; tell us your preferred port or delivery address with your enquiry.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are French; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Temperature controllers in Reunion: common questions

What does defrost control do?

It stops the compressor and turns on a heater, or lets the fans warm the coil, to melt frost off the evaporator at set intervals or until a temperature is reached.

What voltage should temperature controllers be rated for in Reunion?

With a 230 V, 50 Hz supply, Reunion follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every temperature controller against the equipment it serves.

Which standards apply to temperature controllers in Reunion?

Klima temperature controllers follow IEC 60730-1 and IEC 60730-2-9 (temperature sensing controls). In Reunion the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.

How are temperature controllers delivered to Reunion?

Sea freight into Reunion normally clears through ports such as Le Port, with onward delivery by road; urgent parts can travel by air.

Which cities in Reunion can I order temperature controllers for?

Every listed city is covered. The largest are Saint-Denis (155,000), Saint-Paul (105,000), Saint-Pierre (84,000), Le Tampon (82,000) and Saint-Andre (57,000). The country page lists the rest.

What local time and daylight should I plan for in Reunion?

Saint-Denis keeps UTC+4 all year. At 20.9° S there are about 10 h 52 min of daylight in June and about 13 h 24 min in December.

More Klima products for Reunion

Temperature controllers in cities across Reunion