Klima Industries

Klima Thermostats supplied to Mymensingh

Found in Bangladesh, Mymensingh is a smaller city with a humid subtropical climate. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.

The main users of thermostats in Mymensingh are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Mymensingh are welcome.

Country
Bangladesh
Population
225,000
Climate
Humid subtropical
Coordinates
24.8° N, 90.4° E
Time zone
UTC+6 all year
From Dhaka
116 km north
Supply
230 V, 50 Hz

Klima Thermostats models

All Klima products for Mymensingh · Klima Thermostats overview

What Mymensingh demands of thermostats

In Mymensingh, cooling demand peaks through a long, humid summer. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed thermostats and keep control boxes closed with their gaskets intact.

Sun-warmed walls make thermostats read high; place thermostats on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.

Where thermostats go from Mymensingh

Among the 59 listed cities in Bangladesh, Mymensingh comes 21st by population, with about 0.7% of the listed urban population, about 2.2% of the size of Dhaka, the largest. Mymensingh lies about 116 km north of Dhaka, the capital. For scale, Kumba in Cameroon has a similar population (225,000).

The closest are Netrakona (35 km north-east), Sherpur (49 km north-west) and Jamalpur (50 km west). 13 other listed cities lie within 100 km, and 55 within 300 km. At the other extreme, Cox's Bazar is about 404 km south-east of Mymensingh, the furthest listed city in Bangladesh.

CityDistancePeopleWhat wears thermostats first
Netrakona35 km north-east79,000condensation inside enclosures
Sherpur49 km north-west107,000condensation inside enclosures
Jamalpur50 km west168,000sensor drift and setpoints creeping
Kishorganj52 km south-east91,000condensation inside enclosures
Sarishabari58 km west81,000sensor drift and setpoints creeping
Tangail75 km south-west180,000condensation inside enclosures

In a smaller city like Mymensingh, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Daylight and sun angle in Mymensingh

Mymensingh keeps UTC+6 all year.

At 24.8° N, Mymensingh has about 13 h 40 min of daylight at the June solstice and about 10 h 36 min at the December solstice. The noon sun stands 89° above the horizon in June and 42° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Mymensingh has a humid subtropical climate, the same as the country as a whole, and 37 other listed cities share it.

Typical uses of thermostats in Mymensingh

In Mymensingh, these are the jobs that most often call for thermostats:

  • Domestic and commercial refrigerators and freezers
  • Fan coil units in hotels, offices and hospitals
  • Cold rooms, display cabinets and beverage coolers

Klima thermostats models

ModelTypeTemperature range (°C)Supply (V)
Klima WiFi Room ThermostatWiFi room thermostat5 to 35230 V AC
Klima Fan Coil Thermostat, 3-SpeedFan coil thermostat10 to 30230 V AC
Klima Fridge Thermostat, CapillaryFridge thermostat-25 to +15Switching 230 V AC
Klima Freezer Thermostat, CapillaryFreezer thermostat-35 to -5Switching 230 V AC

See the full Klima Thermostats range for specifications, standards and a plain-language guide to choosing the right part.

Choosing thermostats for Mymensingh

  • For fan coils, confirm 2-pipe or 4-pipe operation and whether the valve is on/off or modulating.
  • For humid subtropical conditions in Mymensingh, favour sealed, corrosion-resistant construction.

Keeping thermostats reliable in Mymensingh

  • Replace batteries on battery-powered models before the seasonal peaks, and check the displayed temperature against a reference thermometer once a year.

Because Mymensingh is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service thermostats in April or May, while the load is still light. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Signs of trouble

  • No response from the screen, or no relay click

Supply and delivery to Mymensingh

Shipments for Mymensingh normally clear customs at one of the main entry points of Bangladesh and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Bangladesh are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Thermostats in Mymensingh: common questions

Where should I install a thermostat?

On an interior wall about 1.2 to 1.5 m above the floor, away from direct sunlight, supply air, kitchens and exterior doors.

What voltage should thermostats be rated for in Mymensingh?

The mains supply in Bangladesh is 230 V, 50 Hz. Match thermostats to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are thermostats delivered to Mymensingh?

To order thermostats for Mymensingh, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Mymensingh can I order for?

Enquiries are welcome from every part of Mymensingh. Send the delivery address with your enquiry.

Which cities near Mymensingh can the same order serve?

The listed cities closest to Mymensingh are Netrakona (35 km north-east), Sherpur (49 km north-west) and Jamalpur (50 km west). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Mymensingh?

Mymensingh keeps UTC+6 all year. At 24.8° N there are about 13 h 40 min of daylight in June and about 10 h 36 min in December.

More Klima products for Mymensingh

Thermostats in cities near Mymensingh