Klima Dial Duct Thermometer
Dial thermometer for duct and coil readings.
Klima Thermometers for HVAC · Model KTH-D1
About this thermometer
The KTH-D1 is a dial thermometer with a stem, reading -40 to 60 °C with an accuracy of ±2 °C. It has no battery and no electronics: the reading is mechanical, so it can stay in a duct or beside a coil and be read at a glance on every visit, with nothing to charge or replace. Its stated use is duct and coil readings.
A dial is an indicator, and the accuracy figure decides what it is good for. With ±2 °C on each of two dials, one in the return duct and one in the supply, the difference between them can be wrong by up to 4 K in the worst case. That is enough to show that a coil is cooling, or that the split has been shrinking over the months, but not enough to diagnose a refrigerant circuit. Treat it as a trend indicator for the people who look after the plant, and use a digital or clamp thermometer when the number matters.
Specifications
| Specification | Value |
|---|---|
| Model | KTH-D1 |
| Type | Dial |
| Range | -40 to 60 °C |
| Accuracy | ±2 °C |
| Probe / sensor | Stem |
| Power | None |
| Typical use | Duct and coil readings |
Where it fits
- Permanent supply and return temperature indication in air handler ducts
- Coil outlet and plant-room readings that should be visible at a glance
- Places where batteries are a nuisance, since there is nothing to replace
- Offices, schools and shops where staff can see that the cooling is working
Fitting and checking
Make an access hole the size of the stem, push the stem in so its tip sits in the middle of the air stream and not against the duct wall, and seal around it with tape or mastic so that the duct does not leak. Mount the dial where it can be read from the floor. Compare it with a reference thermometer when you install it, because a dial can be knocked; replace it if the pointer sticks or the glass fogs with moisture.
Compared with the other HVAC thermometers
This model is one of 3 in Klima Thermometers for HVAC; what changes from one to the next is type, range and accuracy.
| Specification | This model | Across the range |
|---|---|---|
| Type | Dial | Digital probe / Pipe clamp / Dial |
| Range | -40 to 60 °C | -50 to 300 / -40 to 120 / -40 to 60 |
| Accuracy | ±2 °C | ±1 °C / ±0.5 °C / ±2 °C |
| Probe / sensor | Stem | Stainless probe / Clamp sensor / Stem |
| Power | None | Battery / None |
The closest alternative in the range is Klima Digital Probe Thermometer, which shares 0 of the 7 listed specifications and differs in type, range and accuracy. Quote the model code KTH-D1 when you enquire.
Questions
Why choose a dial over a digital thermometer?
There is no battery and nothing electronic to fail, and it can stay in place. The price is a looser ±2 °C accuracy.
Can it be used on refrigerant lines?
It is made for duct air and coil readings in a -40 to 60 °C range. For refrigerant line temperature use the pipe clamp model.
Selection, care and fault-finding notes for the whole family are on the Klima Thermometers for HVAC page, and the contact page takes enquiries with the model code KTH-D1. For background reading, see the guide Superheat and subcooling: measuring with the right thermometer.