Netanya: Klima Thermostats
Found in Israel, Netanya is a smaller city with a Mediterranean climate. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Thermostats are bought here mainly for offices, shops and malls as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Netanya are welcome.
- Country
- Israel
- Population
- 228,000
- Climate
- Mediterranean
- Coordinates
- 32.3° N, 34.9° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Jerusalem
- 71 km north-west
- Supply
- 230 V, 50 Hz
Klima Thermostats models
- Klima WiFi Room Thermostat Type: WiFi room thermostat, Temperature range: 5 to 35 °C, Supply: 230 V AC
- Klima Fan Coil Thermostat, 3-Speed Type: Fan coil thermostat, Temperature range: 10 to 30 °C, Supply: 230 V AC
- Klima Fridge Thermostat, Capillary Type: Fridge thermostat, Temperature range: -25 to +15 °C, Supply: Switching 230 V AC
- Klima Freezer Thermostat, Capillary Type: Freezer thermostat, Temperature range: -35 to -5 °C, Supply: Switching 230 V AC
All Klima products for Netanya · Klima Thermostats overview
Conditions in Netanya that affect thermostats
In Netanya, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: thermostats run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Wide temperature variation makes differentials matter; recheck the setting of thermostats so that the compressor does not short-cycle.
Thermostats in Netanya and the cities near it
Among the 20 listed cities in Israel, Netanya comes 7th by population, with about 5% of the listed urban population, about 23% of the size of Jerusalem, the largest. The capital, Jerusalem, is about 71 km away, to the south-east of Netanya. For scale, Sabya in Saudi Arabia has a similar population (228,000).
Nearest to Netanya: Hadera (13 km north), Kfar Saba (18 km south) and Petah Tiqva (27 km south). 18 other listed cities lie within 100 km, and 19 within 300 km. At the other extreme, Beersheba is about 120 km south of Netanya, the furthest listed city in Israel.
| City | Distance | People | What wears thermostats first |
|---|---|---|---|
| Hadera | 13 km north | 97,000 | sensor drift and setpoints creeping |
| Kfar Saba | 18 km south | 110,000 | calibration drift between seasons |
| Petah Tiqva | 27 km south | 254,000 | calibration drift between seasons |
| Bnei Brak | 28 km south | 214,000 | calibration drift between seasons |
| Tel Aviv | 29 km south | 433,000 | sensor drift and setpoints creeping |
| Umm el Fahm | 34 km north-east | 56,000 | sensor drift and setpoints creeping |
In a smaller city like Netanya, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
Daylight and sun angle in Netanya
Netanya keeps UTC+2, moving to UTC+3 while daylight saving applies.
Netanya lies at 32.3° N, 34.9° E. Daylight lasts about 14 h 16 min at the June solstice and about 10 h 01 min in December, with a noon sun 81° and 34° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Netanya has a Mediterranean climate, the same as the country as a whole, and 19 other listed cities share it.
Typical uses of thermostats in Netanya
Typical work in Netanya that needs thermostats:
- Domestic and commercial refrigerators and freezers
- Heating and cooling changeover on heat pumps
- Room control for split and ducted air conditioners
Klima thermostats models
| Model | Type | Temperature range (°C) | Supply (V) |
|---|---|---|---|
| Klima WiFi Room Thermostat | WiFi room thermostat | 5 to 35 | 230 V AC |
| Klima Fan Coil Thermostat, 3-Speed | Fan coil thermostat | 10 to 30 | 230 V AC |
| Klima Fridge Thermostat, Capillary | Fridge thermostat | -25 to +15 | Switching 230 V AC |
| Klima Freezer Thermostat, Capillary | Freezer thermostat | -35 to -5 | Switching 230 V AC |
See the full Klima Thermostats range for specifications, standards and a plain-language guide to choosing the right part.
Selecting thermostats in Netanya
- For fan coils, confirm 2-pipe or 4-pipe operation and whether the valve is on/off or modulating.
- Ask for the datasheet and the documents your project needs; in Israel that usually means SII (Standards Institution of Israel) requirements.
Keeping thermostats reliable in Netanya
- Mount at 1.2 to 1.5 m height on an internal wall away from sun, draughts and heat sources; a poorly placed thermostat gives false readings.
Because Netanya is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service thermostats in April or May, while the load is still light. Controls drift over time; verify setpoints and switch points before the demanding months.
Signs of trouble
- A WiFi thermostat dropping off the network
Supply and delivery to Netanya
Shipments for Netanya normally clear customs at one of the main entry points of Israel and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Israel are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about thermostats in Netanya
What differential should I set?
For comfort cooling, 0.5 to 1 °C is common. Refrigeration thermostats use a wider cut-in and cut-out span set by the equipment maker. Narrower bands make the compressor cycle more often.
What voltage should thermostats be rated for in Netanya?
The mains supply in Israel is 230 V, 50 Hz. Match thermostats to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are thermostats delivered to Netanya?
To order thermostats for Netanya, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Netanya can I order for?
Enquiries are welcome from every part of Netanya. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Netanya?
Netanya keeps UTC+2, moving to UTC+3 while daylight saving applies. At 32.3° N there are about 14 h 16 min of daylight in June and about 10 h 01 min in December.
Which cities near Netanya can the same order serve?
The listed cities closest to Netanya are Hadera (13 km north), Kfar Saba (18 km south) and Petah Tiqva (27 km south). Combine them into one order and give each delivery address.
More Klima products for Netanya
- Klima Temperature Controllers in Netanya
- Klima Thermostat Guards in Netanya
- Klima Transformer for HVAC in Netanya
- Klima Filter Driers in Netanya
- Klima Terminal Crimps in Netanya
- Klima Copper Coils & Tubes in Netanya