Klima copper coils and tubes for Netanya
With about 228,000 people, Netanya is a smaller city in Israel. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Demand for copper coils and tubes comes mostly from offices, shops and malls as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Netanya.
- Country
- Israel
- Population
- 228,000
- Climate
- Mediterranean
- Coordinates
- 32.3° N, 34.9° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Jerusalem
- 71 km north-west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Netanya · Klima Copper Coils & Tubes overview
Conditions in Netanya that affect copper coils and tubes
In Netanya, cooling demand peaks from late spring to early autumn. In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Changeable weather means wind one hour and still air the next; carry a heat shield and a wind screen, and re-check the flame at each joint.
Where copper coils and tubes go from Netanya
Among the 20 listed cities in Israel, Netanya comes 7th by population, with about 5% of the listed urban population, about 23% of the size of Jerusalem, the largest. From Jerusalem, the capital, Netanya is roughly 71 km to the north-west. For scale, Sabya in Saudi Arabia has a similar population (228,000).
Nearest to Netanya: Hadera (13 km north), Kfar Saba (18 km south) and Petah Tiqva (27 km south). 18 other listed cities lie within 100 km, and 19 within 300 km.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Hadera | 13 km north | 97,000 | joint fatigue from temperature swings |
| Kfar Saba | 18 km south | 110,000 | high head pressure and hot joints |
| Petah Tiqva | 27 km south | 254,000 | joint fatigue from temperature swings |
| Bnei Brak | 28 km south | 214,000 | joint fatigue from temperature swings |
| Tel Aviv | 29 km south | 433,000 | joint fatigue from temperature swings |
| Umm el Fahm | 34 km north-east | 56,000 | high head pressure and hot joints |
In a smaller city like Netanya, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Time zone, sun and daylight in Netanya
Netanya keeps UTC+2, moving to UTC+3 while daylight saving applies.
At 32.3° N, Netanya has about 14 h 16 min of daylight at the June solstice and about 10 h 01 min at the December solstice. The noon sun stands 81° above the horizon in June and 34° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Netanya has a Mediterranean climate, the same as the country as a whole, and 19 other listed cities share it.
Jobs in Netanya that call for copper coils and tubes
In Netanya, these are the jobs that most often call for copper coils and tubes:
- Condensing unit to evaporator lines in cold rooms
- Heat pump refrigerant lines
- Split-system liquid and suction lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Choosing copper coils and tubes for Netanya
- Order enough length for the full run plus waste for bends and brazing off-cuts.
- Ask for the datasheet and the documents your project needs; in Israel that usually means SII (Standards Institution of Israel) requirements.
Care and maintenance in Netanya
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
Because Netanya is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service copper coils and tubes in April or May, while the load is still light. Replace driers and re-braze suspect joints while the system can be stopped without complaints.
Faults to watch for
- A system that loses charge slowly
Supply and delivery to Netanya
Shipments for Netanya normally clear customs at one of the main entry points of Israel and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Israel are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Copper coils and tubes in Netanya: common questions
What wall thickness do I need for R410A?
R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.
How does the climate in Netanya affect copper coils and tubes?
High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
How are copper coils and tubes delivered to Netanya?
To order copper coils and tubes for Netanya, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Netanya can I order for?
Enquiries are welcome from every part of Netanya. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Netanya?
Netanya keeps UTC+2, moving to UTC+3 while daylight saving applies. At 32.3° N there are about 14 h 16 min of daylight in June and about 10 h 01 min in December.
Which cities near Netanya can the same order serve?
The listed cities closest to Netanya are Hadera (13 km north), Kfar Saba (18 km south) and Petah Tiqva (27 km south). Combine them into one order and give each delivery address.
More Klima products for Netanya
- Klima Filter Driers in Netanya
- Klima Flux Powder (100 g & 250 g) in Netanya
- Klima Map Gas (Brazing & Welding) in Netanya
- Klima Cables (3 & 4 Core) in Netanya
- Klima Terminal Crimps in Netanya
- Klima Thermometers for HVAC in Netanya