Klima Industries

Klima Cables (3 & 4 Core) in Kita

Found in Mali, Kita is a smaller city with a hot and arid climate. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

The main users of cables in Kita are offices, shops and malls as well as homes and apartments. Klima Industries lists 6 models in this range with full specifications below, and enquiries from Kita are welcome.

Country
Mali
Population
76,000
Climate
Hot and arid
Coordinates
13.0° N, 9.5° W
Time zone
UTC+0 all year
From Bamako
171 km west
Supply
230 V, 50 Hz

Klima Cables (3 & 4 Core) models

All Klima products for Kita · Klima Cables (3 & 4 Core) overview

Cables and the climate in Kita

In Kita, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: cables run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Fine dust settles on cables and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.

Where cables go from Kita

Kita ranks 11th of the 25 listed cities in Mali and holds about 1.2% of the people living in them, roughly 1.8% of the size of the largest city, Bamako. From Bamako, the capital, Kita is roughly 171 km to the west. For scale, Bihac in Bosnia and Herzegovina has a similar population (76,000).

In the directory the nearest cities are Kolokani (168 km east), Bamako (171 km east) and Koulikoro (210 km east). No other listed city lies within 100 km, and seven lie within 300 km. At the other extreme, Kidal is about 1,311 km north-east of Kita, the furthest listed city in Mali.

CityDistancePeopleWhat wears cables first
Kolokani168 km east49,000dust on contacts and blocked cooling
Bamako171 km east4.2 milliondust on contacts and blocked cooling
Koulikoro210 km east64,000terminals loosening and parts running hot
Nioro244 km north52,000dust on contacts and blocked cooling
Kayes263 km north-west195,000terminals loosening and parts running hot
Fana276 km east57,000dust on contacts and blocked cooling

In a smaller city like Kita, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

The sun and the clock in Kita

Local time in Kita is UTC+0 all year.

Kita lies at 13.0° N, 9.5° W. Daylight lasts about 12 h 54 min at the June solstice and about 11 h 21 min in December, with a noon sun 80° and 54° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Kita has a hot and arid climate, the same as the country as a whole, and 24 other listed cities share it.

Typical uses of cables in Kita

Typical work in Kita that needs cables:

  • Building refurbishment and retrofit work
  • Indoor-to-outdoor interconnecting cable for split ACs
  • Fan coil unit and VRF branch wiring

Klima cables models

ModelCoresConductor size (mm²)Insulation
Klima 3-Core Flexible Cable 1.5 mm²31.5PVC
Klima 3-Core Flexible Cable 2.5 mm²32.5PVC
Klima 3-Core Flexible Cable 4 mm²34PVC
Klima 4-Core Flexible Cable 1.5 mm²41.5PVC

See the full Klima Cables (3 & 4 Core) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting cables in Kita

  • Avoid splices inside walls; use terminal blocks in accessible enclosures.
  • Confirm the supply first: Mali uses 230 V at 50 Hz, so check the voltage and frequency rating of cables against the equipment nameplate.

Keeping cables reliable in Kita

  • Support outdoor runs with clips or conduit so the sheath does not chafe or sag.

Because Kita is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service cables in March or April, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Faults to watch for

  • Discoloured or brittle sheathing near hot refrigerant lines

Getting cables to Kita

To order cables for Kita, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Mali are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Cables in Kita: common questions

Can I use PVC cable outdoors?

Yes where it is protected from direct sunlight and mechanical damage, for example inside conduit or trunking. Exposed runs benefit from UV-resistant cable or extra protection.

What voltage should cables be rated for in Kita?

With a 230 V, 50 Hz supply, Mali follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every cable against the equipment it serves.

How are cables delivered to Kita?

Shipments for Kita normally clear customs at one of the main entry points of Mali and finish the journey by road; send your delivery address with the enquiry.

Which parts of Kita can I order for?

Enquiries are welcome from every part of Kita. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Kita?

Kita keeps UTC+0 all year. At 13.0° N there are about 12 h 54 min of daylight in June and about 11 h 21 min in December.

Which cities near Kita can the same order serve?

The listed cities closest to Kita are Kolokani (168 km east), Bamako (171 km east) and Koulikoro (210 km east). Combine them into one order and give each delivery address.

More Klima products for Kita

Cables in cities near Kita