Capacitors for Fier-Cifci
Fier-Cifci is a smaller city in Albania. The climate is Mediterranean. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
The main users of capacitors in Fier-Cifci are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Fier-Cifci are welcome.
- Country
- Albania
- Population
- 61,000
- Climate
- Mediterranean
- Coordinates
- 40.7° N, 19.6° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Tirana
- 71 km south
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Fier-Cifci · Klima Capacitors overview
Capacitors and the climate in Fier-Cifci
In Fier-Cifci, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Cities around Fier-Cifci that need capacitors
Fier-Cifci ranks 8th of the 15 listed cities in Albania and holds about 4.3% of the people living in them, roughly 15% of the size of the largest city, Tirana. From Tirana, the capital, Fier-Cifci is roughly 71 km to the south. It is about the same size as Valjevo in Serbia, which has 61,000.
In the directory the nearest cities are Fier (1 km north-west), Lushnje (28 km north-east) and Vlore (28 km south). 11 other listed cities lie within 100 km, and 14 within 300 km. The farthest listed city in Albania is Kukes, about 167 km north-east of Fier-Cifci.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Fier | 1 km north-west | 56,000 | expansion and contraction loosening joints |
| Lushnje | 28 km north-east | 63,000 | terminals loosening and parts running hot |
| Vlore | 28 km south | 115,000 | terminals loosening and parts running hot |
| Kucove | 31 km east | 31,000 | expansion and contraction loosening joints |
| Berat | 33 km east | 62,000 | terminals loosening and parts running hot |
| Kavaje | 52 km north | 30,000 | terminals loosening and parts running hot |
In a smaller city like Fier-Cifci, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Fier-Cifci
Fier-Cifci keeps UTC+1, moving to UTC+2 while daylight saving applies.
Sunlight at 40.7° N (Fier-Cifci): about 15 h 06 min of daylight in June, about 9 h 15 min in December, and a noon sun that reaches 73° in June and 26° in December. The sun climbs high in summer, so shade and ventilation around outdoor units matter. The climate in Fier-Cifci is Mediterranean, in line with the rest of Albania; 14 other listed cities share it.
Jobs in Fier-Cifci that call for capacitors
Typical work in Fier-Cifci that needs capacitors:
- Fan coil unit and blower motors
- Ventilation and exhaust fan motors
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Fier-Cifci
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: Albania uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Fier-Cifci
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check capacitors in Fier-Cifci. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Fier-Cifci
To order capacitors for Fier-Cifci, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Albania are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Fier-Cifci: common questions
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Fier-Cifci?
The mains supply in Albania is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Fier-Cifci?
Shipments for Fier-Cifci normally clear customs at one of the main entry points of Albania and finish the journey by road; send your delivery address with the enquiry.
Which parts of Fier-Cifci can I order for?
Enquiries are welcome from every part of Fier-Cifci. Send the delivery address with your enquiry.
Which cities near Fier-Cifci can the same order serve?
The listed cities closest to Fier-Cifci are Fier (1 km north-west), Lushnje (28 km north-east) and Vlore (28 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Fier-Cifci?
Fier-Cifci keeps UTC+1, moving to UTC+2 while daylight saving applies. At 40.7° N there are about 15 h 06 min of daylight in June and about 9 h 15 min in December.
More Klima products for Fier-Cifci
- Klima Contactors in Fier-Cifci
- Klima Terminal Crimps in Fier-Cifci
- Klima Transformer for HVAC in Fier-Cifci
- Klima Drier Core 48-KL in Fier-Cifci
- Klima Delay on Make Timer in Fier-Cifci
- Klima Copper Coils & Tubes in Fier-Cifci