Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Orsha · Klima Capacitors overview
What Orsha demands of capacitors
In Orsha, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Low temperatures make plastics brittle and slow some electrical parts; let cold capacitors warm up before fitting where you can, and never force a terminal.
Cities around Orsha that need capacitors
Orsha ranks 13th of the 20 listed cities in Belarus and holds about 2% of the people living in them, about 5.8% of the size of Minsk, the largest. Orsha lies about 197 km east of Minsk, the capital. It is about the same size as Szekesfehervar in Hungary, which has 102,000.
In the directory the nearest cities are Mahilyow (67 km south), Vitebsk (76 km north) and Barysaw (127 km west). Two other listed cities lie within 100 km, and 14 within 300 km. At the other extreme, Brest is about 518 km south-west of Orsha, the furthest listed city in Belarus.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Mahilyow | 67 km south | 353,000 | brittle insulation and hard starting |
| Vitebsk | 76 km north | 359,000 | brittle insulation and hard starting |
| Barysaw | 127 km west | 134,000 | brittle insulation and hard starting |
| Horad Zhodzina | 142 km west | 63,000 | expansion and contraction loosening joints |
| Polotsk | 150 km north-west | 79,000 | expansion and contraction loosening joints |
| Novopolotsk | 161 km north-west | 95,000 | expansion and contraction loosening joints |
In a smaller city like Orsha, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Daylight and sun angle in Orsha
Orsha keeps UTC+3 all year.
Orsha lies at 54.5° N, 30.4° E. Daylight lasts about 17 h 16 min at the June solstice and about 7 h 16 min in December, with a noon sun 59° and 12° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Orsha is continental, in line with the rest of Belarus; 19 other listed cities share it.
Typical uses of capacitors in Orsha
Capacitors are most often specified in Orsha for:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Orsha
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- For continental conditions in Orsha, allow for wide seasonal temperature swings.
Keeping capacitors reliable in Orsha
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Because Orsha is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service capacitors in April or May, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Orsha
Shipments for Orsha normally clear customs at one of the main entry points of Belarus and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Belarus are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Orsha
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Orsha?
The mains supply in Belarus is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Orsha?
To order capacitors for Orsha, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Orsha can I order for?
Enquiries are welcome from every part of Orsha. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Orsha?
Orsha keeps UTC+3 all year. At 54.5° N there are about 17 h 16 min of daylight in June and about 7 h 16 min in December.
Which cities near Orsha can the same order serve?
The listed cities closest to Orsha are Mahilyow (67 km south), Vitebsk (76 km north) and Barysaw (127 km west). Combine them into one order and give each delivery address.
More Klima products for Orsha
- Klima Contactors in Orsha
- Klima Terminal Crimps in Orsha
- Klima Transformer for HVAC in Orsha
- Klima Condensate Pump in Orsha
- Klima Thermometers for HVAC in Orsha
- Klima Thermostat Guards in Orsha