Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Pobe · Klima Capacitors overview
Conditions in Pobe that affect capacitors
In Pobe, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Cities around Pobe that need capacitors
Pobe ranks 13th of the 22 listed cities in Benin and holds about 1.9% of the people living in them, roughly 7.3% of the size of the largest city, Cotonou. Pobe lies about 54 km north of Porto-Novo, the capital. For scale, Whanganui in New Zealand has a similar population (49,000).
Nearest to Pobe: Sakete (27 km south), Ketou (43 km north) and Cove (45 km north-west). 10 other listed cities lie within 100 km, and 15 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Sakete | 27 km south | 44,000 | terminals loosening and parts running hot |
| Ketou | 43 km north | 40,000 | terminals loosening and parts running hot |
| Cove | 45 km north-west | 44,000 | moisture on terminals and corrosion |
| Porto-Novo | 54 km south | 264,000 | moisture on terminals and corrosion |
| Abomey-Calavi | 68 km south-west | 386,000 | terminals loosening and parts running hot |
| Bohicon | 70 km west | 94,000 | moisture on terminals and corrosion |
In a smaller city like Pobe, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Pobe
The clock in Pobe follows UTC+1 all year.
At 7.0° N, Pobe has about 12 h 32 min of daylight at the June solstice and about 11 h 43 min at the December solstice. The noon sun stands 74° above the horizon in June and 60° in December, and the sun climbs high in summer, so shade and ventilation around outdoor units matter. Pobe has a hot and humid tropical climate, the same as the country as a whole, and 21 other listed cities share it.
Jobs in Pobe that call for capacitors
Capacitors are most often specified in Pobe for:
- Split and window air conditioners
- Heat pump outdoor units
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Pobe
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- For hot and humid tropical conditions in Pobe, favour sealed, corrosion-resistant construction.
Care and maintenance in Pobe
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
A tropical climate keeps cooling demand steady through the year in Pobe, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Ordering capacitors for Pobe
To order capacitors for Pobe, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Benin are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Pobe
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in Pobe?
Benin supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Pobe?
Shipments for Pobe normally clear customs at one of the main entry points of Benin and finish the journey by road; send your delivery address with the enquiry.
Which parts of Pobe can I order for?
Enquiries are welcome from every part of Pobe. Send the delivery address with your enquiry.
Which cities near Pobe can the same order serve?
The listed cities closest to Pobe are Sakete (27 km south), Ketou (43 km north) and Cove (45 km north-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Pobe?
Pobe keeps UTC+1 all year. At 7.0° N there are about 12 h 32 min of daylight in June and about 11 h 43 min in December.
More Klima products for Pobe
- Klima Contactors in Pobe
- Klima Terminal Crimps in Pobe
- Klima Transformer for HVAC in Pobe
- Klima Filter Driers in Pobe
- Klima Temperature Controllers in Pobe
- Klima Flux Powder (100 g & 250 g) in Pobe