The main users of capacitors in Bavet are offices, shops and malls as well as factories and workshops. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Bavet.
- Country
- Cambodia
- Population
- 44,000
- Climate
- Hot and humid tropical
- Coordinates
- 11.1° N, 106.1° E
- Time zone
- UTC+7 all year
- From Phnom Penh
- 144 km south-east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Bavet · Klima Capacitors overview
Conditions in Bavet that affect capacitors
In Bavet, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Cities around Bavet that need capacitors
Bavet ranks 11th of the 24 listed cities in Cambodia and holds about 1.3% of the people living in them, roughly 2.8% of the size of the largest city, Phnom Penh. The capital, Phnom Penh, is about 144 km away, to the north-west of Bavet. It is about the same size as Thun in Switzerland, which has 44,000.
The closest are Svay Rieng (37 km west), Dar (81 km north) and Prey Veng (100 km north-west). Three other listed cities lie within 100 km, and 15 within 300 km. At the other extreme, Paoy Paet is about 483 km north-west of Bavet, the furthest listed city in Cambodia.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Svay Rieng | 37 km west | 24,000 | terminals loosening and parts running hot |
| Dar | 81 km north | 23,000 | terminals loosening and parts running hot |
| Prey Veng | 100 km north-west | 33,000 | terminals loosening and parts running hot |
| Suong | 108 km north-west | 30,000 | moisture on terminals and corrosion |
| Kandoeng | 143 km west | 34,000 | terminals loosening and parts running hot |
| Phnom Penh | 144 km north-west | 1.6 million | moisture on terminals and corrosion |
In a smaller city like Bavet, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Daylight and sun angle in Bavet
Bavet keeps UTC+7 all year.
At 11.1° N, Bavet has about 12 h 46 min of daylight at the June solstice and about 11 h 29 min at the December solstice. The noon sun stands 78° above the horizon in June and 55° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Bavet is hot and humid tropical, in line with the rest of Cambodia; 23 other listed cities share it.
Jobs in Bavet that call for capacitors
Capacitors are most often specified in Bavet for:
- Fan coil unit and blower motors
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Bavet
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Ask for the datasheet and the documents your project needs; in Cambodia that usually means ISC (Institute of Standards of Cambodia) requirements.
Care and maintenance in Bavet
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
A tropical climate keeps cooling demand steady through the year in Bavet, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- A swollen, bulging or leaking case
Supply and delivery to Bavet
Shipments for Bavet normally clear customs at one of the main entry points of Cambodia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Cambodia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Bavet: common questions
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Bavet?
Cambodia supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Bavet?
To order capacitors for Bavet, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Bavet can I order for?
Enquiries are welcome from every part of Bavet. Send the delivery address with your enquiry.
Which cities near Bavet can the same order serve?
The listed cities closest to Bavet are Svay Rieng (37 km west), Dar (81 km north) and Prey Veng (100 km north-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Bavet?
Bavet keeps UTC+7 all year. At 11.1° N there are about 12 h 46 min of daylight in June and about 11 h 29 min in December.
More Klima products for Bavet
- Klima Contactors in Bavet
- Klima Terminal Crimps in Bavet
- Klima Transformer for HVAC in Bavet
- Klima Flux Powder (100 g & 250 g) in Bavet
- Klima Map Gas (Brazing & Welding) in Bavet
- Klima Cables (3 & 4 Core) in Bavet