Klima Capacitors supplied to Kumba
Kumba is a smaller city in Cameroon. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Kumba are offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Kumba for a quotation.
- Country
- Cameroon
- Population
- 225,000
- Climate
- Hot and humid tropical
- Coordinates
- 4.6° N, 9.4° E
- Time zone
- UTC+1 all year
- From Yaounde
- 245 km west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Kumba · Klima Capacitors overview
Conditions in Kumba that affect capacitors
In Kumba, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Where capacitors go from Kumba
Among the 28 listed cities in Cameroon, Kumba comes 7th by population, with about 3.6% of the listed urban population, about 17% of the size of Douala, the largest. From Yaounde, the capital, Kumba is roughly 245 km to the west. For scale, Kosice in Slovakia has a similar population (225,000).
In the directory the nearest cities are Buea (58 km south-west), Mutengene (62 km south) and Tiko (63 km south). Seven other listed cities lie within 100 km, and 20 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Buea | 58 km south-west | 141,000 | terminals loosening and parts running hot |
| Mutengene | 62 km south | 64,000 | terminals loosening and parts running hot |
| Tiko | 63 km south | 95,000 | moisture on terminals and corrosion |
| Nkongsamba | 65 km north-east | 162,000 | terminals loosening and parts running hot |
| Douala | 71 km south-east | 1.3 million | terminals loosening and parts running hot |
| Limbe | 73 km south | 131,000 | terminals loosening and parts running hot |
In a smaller city like Kumba, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Kumba
Kumba keeps UTC+1 all year.
Kumba lies at 4.6° N, 9.4° E. Daylight lasts about 12 h 23 min at the June solstice and about 11 h 51 min in December, with a noon sun 71° and 62° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. Kumba has a hot and humid tropical climate, the same as the country as a whole, and 27 other listed cities share it.
Where capacitors are used in Kumba
Typical work in Kumba that needs capacitors:
- Fan coil unit and blower motors
- Heat pump outdoor units
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Kumba
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Confirm the supply first: Cameroon uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Kumba
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
A tropical climate keeps cooling demand steady through the year in Kumba, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A swollen, bulging or leaking case
Supply and delivery to Kumba
To order capacitors for Kumba, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Cameroon are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Kumba
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Kumba?
Cameroon supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Kumba?
Shipments for Kumba normally clear customs at one of the main entry points of Cameroon and finish the journey by road; send your delivery address with the enquiry.
Which parts of Kumba can I order for?
Enquiries are welcome from every part of Kumba. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Kumba?
Kumba keeps UTC+1 all year. At 4.6° N there are about 12 h 23 min of daylight in June and about 11 h 51 min in December.
Which cities near Kumba can the same order serve?
The listed cities closest to Kumba are Buea (58 km south-west), Mutengene (62 km south) and Tiko (63 km south). Combine them into one order and give each delivery address.
More Klima products for Kumba
- Klima Contactors in Kumba
- Klima Terminal Crimps in Kumba
- Klima Transformer for HVAC in Kumba
- Klima Pressure Switches (High & Low) in Kumba
- Klima PVC Tapes in Kumba
- Klima Condensate Pump in Kumba