Buying capacitors in Yopal
With about 168,000 people, Yopal is a smaller city in Colombia. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Yopal are offices, shops and malls as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Yopal for a quotation.
- Country
- Colombia
- Population
- 168,000
- Climate
- Hot and humid tropical
- Coordinates
- 5.3° N, 72.4° W
- Time zone
- UTC-5 all year
- From Bogota
- 204 km north-east
- Supply
- 110 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Yopal · Klima Capacitors overview
Conditions in Yopal that affect capacitors
In Yopal, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Cities around Yopal that need capacitors
By population Yopal is 28th of the 35 cities listed for Colombia, with roughly 0.7% of their combined population, about 2.2% of the size of Bogota, the largest. From Bogota, the capital, Yopal is roughly 204 km to the north-east. It is about the same size as Ituzaingo in Argentina, which has 168,000.
Nearest to Yopal: Tunja (109 km west), Zipaquira (182 km west) and Villavicencio (191 km south-west). No other listed city lies within 100 km, and 10 lie within 300 km. The farthest listed city in Colombia is Pasto, about 710 km south-west of Yopal.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Tunja | 109 km west | 173,000 | terminals loosening and parts running hot |
| Zipaquira | 182 km west | 130,000 | moisture on terminals and corrosion |
| Villavicencio | 191 km south-west | 322,000 | moisture on terminals and corrosion |
| Piedecuesta | 197 km north | 163,000 | terminals loosening and parts running hot |
| Bogota | 204 km south-west | 7.7 million | reduced cooling and thinner air at altitude |
| Floridablanca | 207 km north | 268,000 | moisture on terminals and corrosion |
In a smaller city like Yopal, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Yopal
The clock in Yopal follows UTC-5 all year.
Sunlight at 5.3° N (Yopal): about 12 h 26 min of daylight in June, about 11 h 49 min in December, and a noon sun that reaches 72° in June and 61° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat. Unlike the highland country as a whole, Yopal is hot and humid tropical; 32 other listed cities share it.
Where capacitors are used in Yopal
Typical work in Yopal that needs capacitors:
- Split and window air conditioners
- Commercial display fridges and freezers
- Condensing units for walk-in cold rooms
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Yopal
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Ask for the datasheet and the documents your project needs; in Colombia that usually means the RETIE technical regulation for electrical products and ICONTEC standards.
Keeping capacitors reliable in Yopal
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
A tropical climate keeps cooling demand steady through the year in Yopal, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Yopal
To order capacitors for Yopal, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Colombia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Yopal: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Yopal?
Colombia supplies 110 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
How are capacitors delivered to Yopal?
Shipments for Yopal normally clear customs at one of the main entry points of Colombia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Yopal can I order for?
Enquiries are welcome from every part of Yopal. Send the delivery address with your enquiry.
Which cities near Yopal can the same order serve?
The listed cities closest to Yopal are Tunja (109 km west), Zipaquira (182 km west) and Villavicencio (191 km south-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Yopal?
Yopal keeps UTC-5 all year. At 5.3° N there are about 12 h 26 min of daylight in June and about 11 h 49 min in December.
More Klima products for Yopal
- Klima Contactors in Yopal
- Klima Terminal Crimps in Yopal
- Klima Transformer for HVAC in Yopal
- Klima Condensate Pump in Yopal
- Klima Thermostats in Yopal
- Klima Drier Core 48-KL in Yopal