Pilsen: Klima Capacitors
With about 169,000 people, Pilsen is a smaller city in the Czech Republic. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Capacitors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Pilsen.
- Country
- Czech Republic
- Population
- 169,000
- Climate
- Continental
- Coordinates
- 49.7° N, 13.4° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Prague
- 84 km south-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Pilsen · Klima Capacitors overview
Capacitors and the climate in Pilsen
In Pilsen, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
Cities around Pilsen that need capacitors
Pilsen ranks 4th of the 21 listed cities in the Czech Republic and holds about 5.4% of the people living in them, about 14% of the size of Prague, the largest. The capital, Prague, is about 84 km away, to the north-east of Pilsen. For scale, San Miguel in Argentina has a similar population (169,000).
In the directory the nearest cities are Karlovy Vary (65 km north-west), Chomutov (79 km north) and Prague (84 km north-east). Four other listed cities lie within 100 km, and 15 within 300 km. At the other extreme, Karvina is about 371 km east of Pilsen, the furthest listed city in the Czech Republic.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Karlovy Vary | 65 km north-west | 46,000 | brittle insulation and hard starting |
| Chomutov | 79 km north | 47,000 | brittle insulation and hard starting |
| Prague | 84 km north-east | 1.2 million | brittle insulation and hard starting |
| Most | 86 km north | 63,000 | expansion and contraction loosening joints |
| Teplice | 104 km north | 51,000 | expansion and contraction loosening joints |
| Usti nad Labem | 112 km north-east | 90,000 | expansion and contraction loosening joints |
In a smaller city like Pilsen, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Pilsen
The clock in Pilsen follows UTC+1, moving to UTC+2 while daylight saving applies.
Pilsen lies at 49.7° N, 13.4° E. Daylight lasts about 16 h 20 min at the June solstice and about 8 h 07 min in December, with a noon sun 64° and 17° high; the sun climbs high in summer, so shade and ventilation around outdoor units matter. Pilsen has a continental climate, the same as the country as a whole, and 20 other listed cities share it.
Typical uses of capacitors in Pilsen
Capacitors are most often specified in Pilsen for:
- Split and window air conditioners
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Pilsen
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Ask for the datasheet and the documents your project needs; in the Czech Republic that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.
Keeping capacitors reliable in Pilsen
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Pilsen is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service capacitors in April or May, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Ordering capacitors for Pilsen
Shipments for Pilsen normally clear customs at one of the main entry points of the Czech Republic and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for the Czech Republic are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Pilsen
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Pilsen?
The mains supply in the Czech Republic is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Pilsen?
To order capacitors for Pilsen, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Pilsen can I order for?
Enquiries are welcome from every part of Pilsen. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Pilsen?
Pilsen keeps UTC+1, moving to UTC+2 while daylight saving applies. At 49.7° N there are about 16 h 20 min of daylight in June and about 8 h 07 min in December.
Which cities near Pilsen can the same order serve?
The listed cities closest to Pilsen are Karlovy Vary (65 km north-west), Chomutov (79 km north) and Prague (84 km north-east). Combine them into one order and give each delivery address.
More Klima products for Pilsen
- Klima Contactors in Pilsen
- Klima Terminal Crimps in Pilsen
- Klima Transformer for HVAC in Pilsen
- Klima Thermostat Guards in Pilsen
- Klima Delay on Make Timer in Pilsen