Klima Capacitors supplied to Santa Ana
With about 177,000 people, Santa Ana is a smaller city in El Salvador. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Santa Ana are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Santa Ana are welcome.
- Country
- El Salvador
- Population
- 177,000
- Climate
- Hot and humid tropical
- Coordinates
- 14.0° N, 89.6° W
- Time zone
- UTC-6 all year
- From San Salvador
- 52 km north-west
- Supply
- 115 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Santa Ana · Klima Capacitors overview
Capacitors and the climate in Santa Ana
In Santa Ana, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Capacitors in Santa Ana and the cities near it
Among the 18 listed cities in El Salvador, Santa Ana comes 4th by population, with about 10% of the listed urban population, about 34% of the size of San Salvador, the largest. The capital, San Salvador, is about 52 km away, to the south-east of Santa Ana. For scale, Nador in Morocco has a similar population (177,000).
The closest are Ahuachapan (32 km west), Sonsonate (35 km south-west) and Aguilares (40 km east). 13 other listed cities lie within 100 km, and 17 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Ahuachapan | 32 km west | 34,000 | terminals loosening and parts running hot |
| Sonsonate | 35 km south-west | 59,000 | terminals loosening and parts running hot |
| Aguilares | 40 km east | 21,000 | moisture on terminals and corrosion |
| Metapan | 40 km north | 19,000 | terminals loosening and parts running hot |
| San Salvador | 52 km south-east | 526,000 | terminals loosening and parts running hot |
| Acajutla | 53 km south-west | 23,000 | moisture on terminals and corrosion |
In a smaller city like Santa Ana, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Santa Ana
The clock in Santa Ana follows UTC-6 all year.
At 14.0° N, Santa Ana has about 12 h 57 min of daylight at the June solstice and about 11 h 18 min at the December solstice. The noon sun stands 81° above the horizon in June and 53° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Santa Ana has a hot and humid tropical climate, the same as the country as a whole, and 17 other listed cities share it.
Jobs in Santa Ana that call for capacitors
Typical work in Santa Ana that needs capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Santa Ana
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Ask for the datasheet and the documents your project needs; in El Salvador that usually means OSARTEC technical regulations.
Keeping capacitors reliable in Santa Ana
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
A tropical climate keeps cooling demand steady through the year in Santa Ana, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Santa Ana
To order capacitors for Santa Ana, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for El Salvador are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Santa Ana: common questions
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Santa Ana?
El Salvador supplies 115 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
How are capacitors delivered to Santa Ana?
Shipments for Santa Ana normally clear customs at one of the main entry points of El Salvador and finish the journey by road; send your delivery address with the enquiry.
Which parts of Santa Ana can I order for?
Enquiries are welcome from every part of Santa Ana. Send the delivery address with your enquiry.
Which cities near Santa Ana can the same order serve?
The listed cities closest to Santa Ana are Ahuachapan (32 km west), Sonsonate (35 km south-west) and Aguilares (40 km east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Santa Ana?
Santa Ana keeps UTC-6 all year. At 14.0° N there are about 12 h 57 min of daylight in June and about 11 h 18 min in December.
More Klima products for Santa Ana
- Klima Contactors in Santa Ana
- Klima Terminal Crimps in Santa Ana
- Klima Transformer for HVAC in Santa Ana
- Klima Flux Powder (100 g & 250 g) in Santa Ana
- Klima Drier Core 48-KL in Santa Ana
- Klima Map Gas (Brazing & Welding) in Santa Ana